Literature DB >> 7556314

Re-occlusion of residual leaks after transcatheter occlusion of patent ductus arteriosus.

F Abbag1, O Galal, F Fadley, S Oufi.   

Abstract

Between March 1990 and November 1993 175 patients underwent successful closure of patent ductus arteriosus using the Rashkind double umbrella device. Of those patients seen on follow up, 13 (9 female, 4 male) had a residual leak and were admitted for implantation of a second device alongside the first device. The interval between the procedures ranged from 6 to 22 months. The mean age at the first procedure was 73.9 months (range 24-204 months) and the mean weight was 18.9kg (range 8.4-64). The mean age at the second procedure was 86.9 months (30-213) and the mean weight was 21.4 kg (8.6-64). The first device was 17 mm in 11 patients and 12 mm in two. The second device was 17 mm in four patients and 12 mm in nine. Four patients required two 17 mm devices in total. There was no difference in the two procedures regarding the fluoroscopy time, procedure time, complications and length of hospital stay. The second procedure was uneventful; however, in one patient the residual ductus had to be dilated before successfully deploying a 12 mm device. Ten patients had immediate total occlusion and three had a trivial leak on echocardiography 24 h later. One of the three patients was found to have total occlusion on Doppler echocardiography 1 year later. The other patients are yet to be seen for follow-up. Hence a total occlusion rate was in 11/13 patients (85%).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7556314     DOI: 10.1007/bf02074825

Source DB:  PubMed          Journal:  Eur J Pediatr        ISSN: 0340-6199            Impact factor:   3.183


  11 in total

1.  Transcatheter occlusion of persistent arterial duct. Report of The European Registry.

Authors: 
Journal:  Lancet       Date:  1992-10-31       Impact factor: 79.321

2.  Frequency of occurrence of residual ductal flow after surgical ligation by color-flow mapping.

Authors:  K E Sørensen; B Kristensen; O K Hansen
Journal:  Am J Cardiol       Date:  1991-03-15       Impact factor: 2.778

3.  Surgical management of patent ductus arteriosus. A review of 413 cases.

Authors:  S A Ghani; R Hashim
Journal:  J R Coll Surg Edinb       Date:  1989-02

4.  Two-dimensional echocardiographic and color flow Doppler evaluation of ductal occlusion with the Rashkind prosthesis.

Authors:  N N Musewe; L N Benson; J F Smallhorn; R M Freedom
Journal:  Circulation       Date:  1989-12       Impact factor: 29.690

5.  Protrusion of the device: a complication of catheter closure of patent ductus arteriosus.

Authors:  J Ottenkamp; J Hess; M D Talsma; T N Buis-Liem
Journal:  Br Heart J       Date:  1992-09

6.  Transcatheter occlusion of the persistently patent ductus arteriosus. Forty-month follow-up and prevalence of residual shunting.

Authors:  M C Hosking; L N Benson; N Musewe; J D Dyck; R M Freedom
Journal:  Circulation       Date:  1991-12       Impact factor: 29.690

7.  Catheter occlusion of the persistently patent ductus arteriosus.

Authors:  J D Dyck; L N Benson; J F Smallhorn; P R McLaughlin; R M Freedom; R D Rowe
Journal:  Am J Cardiol       Date:  1988-11-15       Impact factor: 2.778

8.  Use of a second transcatheter Rashkind arterial duct occluder for persistent flow after implantation of the first device: indications and results.

Authors:  I C Huggon; A H Tabatabaei; S A Qureshi; E J Baker; M Tynan
Journal:  Br Heart J       Date:  1993-06

9.  Experience with 205 procedures of transcatheter closure of ductus arteriosus in 182 patients, with special reference to residual shunts and long-term follow-up.

Authors:  M A Ali Khan; S al Yousef; C E Mullins; W Sawyer
Journal:  J Thorac Cardiovasc Surg       Date:  1992-12       Impact factor: 5.209

10.  Balloon catheter test in patients with atrial septal defect and patent ductus arteriosus.

Authors:  T Sakurai; H Hoshino; Y Suzuki; H Yokoi; K Sakanaka; K Enomoto; N Okada
Journal:  Jpn Heart J       Date:  1980-11
View more
  1 in total

1.  Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder.

Authors:  G Fischer; J Stieh; A Uebing; R Grabitz; H H Kramer
Journal:  Heart       Date:  2001-10       Impact factor: 5.994

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.