Literature DB >> 7554631

Revision total hip arthroplasty using a cementless acetabular component. Technique and results.

C D Silverton1, A G Rosenberg, M B Sheinkop, L R Kull, J O Galante.   

Abstract

Are the midterm results (range, 7-11 years) for revision of the acetabulum with a cementless hemispherical component comparable with other published revision techniques at similar followup? One hundred thirty-eight acetabular revisions for aseptic loosening were done in 132 patients using a cementless hemispherical component coated with titanium mesh and inserted with supplemental screw fixation. Twelve patients died, 9 were lost to followup, and 6 could not return for followup, leaving 111 patients (115 hips) with a mean of 100 months of followup. Thirteen hips required revision (11%): 4 were done for recurrent dislocations, and 6 for sepsis; 3 stable cups were revised (at the time of stem revision). No cup was revised for aseptic loosening. Radiographic review was available for 105 patients (109 hips) at mean 98-month followup (78-135 months). A complete radiolucency was seen in 4% of the cups, a partial progressive radiolucency in 3%, and a partial nonprogressive radiolucency in 54%; no radiolucency was present in 39%. A screw radiolucency was seen in 2%, and osteolysis at the cup margin in 4%. Revision of the acetabulum with a cementless porous-coated hemispherical fiber-metal component is superior to the results reported for acetabular revisions with cement at similar followup.

Entities:  

Mesh:

Year:  1995        PMID: 7554631

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  Structural allograft and primary press-fit cup for severe acetabular deficiency. A minimum 6-year follow-up study.

Authors:  F Traina; F Giardina; M De Clerico; A Toni
Journal:  Int Orthop       Date:  2005-04-05       Impact factor: 3.075

2.  [Operative treatment of congenital hip osteoarthritis with high hip luxation (Crowe type IV)].

Authors:  H Kohlhof; K Ziebarth; S Gravius; D C Wirtz; K A Siebenrock
Journal:  Oper Orthop Traumatol       Date:  2013-10-02       Impact factor: 1.154

3.  Acetabular revision using a total acetabular allograft.

Authors:  Rajesh Malhotra; Vijay Kumar
Journal:  Indian J Orthop       Date:  2009-04       Impact factor: 1.251

Review 4.  Acetabular Cup Revision Arthroplasty Using Morselized Impaction Allograft.

Authors:  Joong-Myung Lee; Tae-Ho Kim
Journal:  Hip Pelvis       Date:  2018-06-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.