Comparison of fluid warmer performance during simulated clinical conditions.

N Patel1, C E Smith, A C Pinchak.   

Abstract

The study evaluated the warming ability and flow rates associated with four fluid warming devices during pressure driven infusion and during wide open gravity driven roller clamp infusion. Warmers tested were the Astotherm, Flotem IIe, Level 1 System 250 and a modified cardioplegia heat exchanger. Fluids tested were crystalloid, red cells diluted with 200 ml, 0.9% saline, and undiluted red cells. The volume of fluid and outlet temperatures (point where i.v. tubing would be attached to the patient) were measured for each fluid and compared among warmers for each flow rate condition. For pressure driven infusion of red cells and crystalloid, the System 250, and modified heat exchanger delivered warmer fluids (33-35 degrees C) at higher flow rates (160-740 ml.min-1) than the Astotherm and Flotem (23-31 degrees C, 44-268 ml.min-1, P < 0.05). For gravity driven infusion, the System 250 delivered the warmest fluids (33-36 degrees C, P < 0.05) compared with the modified heat exchanger (29-35 degrees C), Astotherm (26-32 degrees C) and Flotem (26-27 degrees C). In conclusion, the modified heat exchanger and System 250 were moderately effective (outlet temperature > 32 degrees C) in warming crystalloid and red cells at pressure driven flow rates. Only the System 250 warmed red cells > 35 degrees C at gravity driven flow rates. The Flotem and Astotherm were not effective in warming rapidly infused solutions. None of the warmers tested was able to deliver fluids at normothermia (> 36.5 degrees C).

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7554005     DOI: 10.1007/BF03011886

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  12 in total

1.  Evaluation of the Level 1 Hotline blood warmer.

Authors:  J M Smallman; M Morgan
Journal:  Anaesthesia       Date:  1992-10       Impact factor: 6.955

2.  A comparative study of blood warmer performance.

Authors:  L Uhl; D Pacini; M S Kruskall
Journal:  Anesthesiology       Date:  1992-11       Impact factor: 7.892

3.  Evaluation of a blood warmer that utilizes a 40 degrees C heat exchanger.

Authors:  M S Kruskall; D G Pacini; E R Malynn; L N Button
Journal:  Transfusion       Date:  1990-01       Impact factor: 3.157

Review 4.  Body temperature and anaesthesia.

Authors:  G M Hall
Journal:  Br J Anaesth       Date:  1978-01       Impact factor: 9.166

Review 5.  Hypothermia in the elderly.

Authors:  R C Morrison
Journal:  Int Anesthesiol Clin       Date:  1988

6.  Paradoxical inhibition of decreases in body temperature by use of heated and humidified gases.

Authors:  H H Hendrickx; G E Trahey; M P Argentieri
Journal:  Anesth Analg       Date:  1982-04       Impact factor: 5.108

7.  Continuous arteriovenous rewarming: experimental results and thermodynamic model simulation of treatment for hypothermia.

Authors:  L M Gentilello; V Cortes; S Moujaes; M Viamonte; T L Malinin; C H Ho; G A Gomez
Journal:  J Trauma       Date:  1990-12

8.  Continuous arteriovenous rewarming: rapid reversal of hypothermia in critically ill patients.

Authors:  L M Gentilello; R A Cobean; P J Offner; R W Soderberg; G J Jurkovich
Journal:  J Trauma       Date:  1992-03

9.  Evaluation of a new high-efficiency blood warmer for children.

Authors:  R G Presson; K A Haselby; A P Bezruczko; E Barnett
Journal:  Anesthesiology       Date:  1990-07       Impact factor: 7.892

10.  Unintentional hypothermia is associated with postoperative myocardial ischemia. The Perioperative Ischemia Randomized Anesthesia Trial Study Group.

Authors:  S M Frank; C Beattie; R Christopherson; E J Norris; B A Perler; G M Williams; S O Gottlieb
Journal:  Anesthesiology       Date:  1993-03       Impact factor: 7.892

View more
  3 in total

1.  Comparison of two fluid warming devices for maintaining body core temperature during living donor liver transplantation: Level 1 H-1000 vs. Fluid Management System 2000.

Authors:  Sangbin Han; Junghee Choi; Justin Sangwook Ko; Misook Gwak; Suk-Koo Lee; Gaab-Soo Kim
Journal:  Korean J Anesthesiol       Date:  2014-10-27

2.  Clinical experience with an active intravascular rewarming technique for near-severe hypothermia associated with traumatic injury.

Authors:  Kazutaka Kiridume; Toru Hifumi; Kenya Kawakita; Tomoya Okazaki; Hideyuki Hamaya; Natsuyo Shinohara; Yuko Abe; Koshiro Takano; Masanobu Hagiike; Yasuhiro Kuroda
Journal:  J Intensive Care       Date:  2014-02-18

3.  Impact of parylene coating on heating performance of intravenous fluid warmer: a bench study.

Authors:  Danielle K Bayoro; Herman Groepenhoff; Daniel Hoolihan; Edward A Rose; Michael J Pedro; Andreas D Waldmann
Journal:  BMC Anesthesiol       Date:  2022-02-10       Impact factor: 2.217

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.