| Literature DB >> 7550977 |
P Zuccaro1, I Altieri, M Rosa, A R Passa, S Pichini, R Pacifici.
Abstract
A solid-phase extraction, using Extrelut-1 glass columns, has been applied to urine samples of both passive and active smokers for high-performance liquid chromatographic determination of nicotine and its metabolites cotinine and trans-3'-hydroxycotinine. Chromatography was performed using a reversed-phase LC8DB column and a mobile phase consisting of water-acetonitrile (80:9, v/v) containing 5 ml triethylamine, 670 mg/l sodium heptanesulphonate, and 0.034 M each of K2HPO4 and citric acid (pH 4.4), at a flow-rate of 1.6 ml/min. The results obtained indicate that solid-phase extraction is a reliable and quick procedure which can be applied also to other nicotine metabolites.Entities:
Mesh:
Substances:
Year: 1995 PMID: 7550977 DOI: 10.1016/0378-4347(95)00066-r
Source DB: PubMed Journal: J Chromatogr B Biomed Appl ISSN: 1572-6495