Management of posterior segment foreign bodies and long-term results.

I Karel1, P Diblík.   

Abstract

The management of 158 posterior segment intraocular foreign bodies (IOFB) was retrospectively analyzed: transscleral magnet extraction via the pars plana was used for 40 magnetic IOFB, transscleral extraction via the IOFB bed for 35 magnetic and 4 non-magnetic IOFB, pars plana vitrectomy (PPV) for 44 magnetic and 32 non-magnetic IOFB, and open-sky vitrectomy for 3 non-magnetic IOFB. Final visual acuity of 0.02 and better was achieved in 104 out of 119 magnetic IOFB (87%) and 24 out of 39 non-magnetic IOFB (62%), and final visual acuity 0.05 and better in 79 magnetic IOFB (66%) and 17 non-magnetic IOFB (44%). Transscleral extraction via the IOFB bed under ophthalmoscopic control and IOFB removal by PPV proved to be the operations of choice for an increasing number of IOFB. For magnetic IOFB, these techniques yielded better final functional results than transscleral magnet extraction via the pars plana. Final visual acuity did not depend on the interval between injury and IOFB removal, and with regard to the risk of endophthalmitis, IOFB need not be considered an absolute indication for immediate intervention. IOFB size up to 5 mm2 and initial visual acuity of 0.5 and better were significant positive factors for both magnetic and non-magnetic IOFB.

Entities:  

Mesh:

Year:  1995        PMID: 7549439     DOI: 10.1177/112067219500500208

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   1.922


  4 in total

1.  Retinal detachment after posterior segment intraocular foreign body injuries.

Authors:  A M El-Asrar; S A Al-Amro; N M Khan; D Kangave
Journal:  Int Ophthalmol       Date:  1998       Impact factor: 2.031

2.  Late onset of rhegmatogenous retinal detachments after successful posterior segment intraocular foreign body removal.

Authors:  D J Weissgold; P Kaushal
Journal:  Br J Ophthalmol       Date:  2005-03       Impact factor: 4.638

3.  Visual outcome and prognostic factors after magnetic extraction of posterior segment foreign bodies in 40 cases.

Authors:  C Chiquet; J C Zech; P Gain; P Adeleine; C Trepsat
Journal:  Br J Ophthalmol       Date:  1998-07       Impact factor: 4.638

4.  23 gauge pars plana vitrectomy for the removal of retained intraocular foreign bodies.

Authors:  Kemal Yuksel; Ugur Celik; Cengiz Alagoz; Huseyin Dundar; Burcu Celik; Ahmet Taylan Yazıcı
Journal:  BMC Ophthalmol       Date:  2015-07-16       Impact factor: 2.209

  4 in total