Literature DB >> 7549198

MR cholangiopancreatography: comparison between two-dimensional fast spin-echo and three-dimensional gradient-echo pulse sequences.

C Reinhold1, L Guibaud, G Genin, P M Bret.   

Abstract

The purpose of our study was to perform a prospective comparative analysis of three-dimensional (3D) steady-state free precession (SSFP) and two-dimensional (2D) fast spin-echo (FSE) imaging in the evaluation of 26 patients with suspected bile duct obstruction. SSFP and highly T2-weighted FSE sequences were obtained for each patient in multiple planes. Both sequences were reviewed independently and results were compared with findings from direct cholangiography (n = 17) or from a combination of sonography and CT (n = 9). The extrahepatic bile duct [EHBD] and intrahepatic bile duct [IHBD] were dilated in 32% and 54% of patients, respectively. The EHBDs were visualized in 44% of patients with SSFP, versus in 96% with FSE. One or more IHBD segments were seen in 42% of the SSFP sequences and in 100% of the FSE sequences. A portion of, or the entire, pancreatic duct was seen in 23% of the SSFP sequences and in 65% of the FSE sequences. Our findings lead us to conclude that T2-weighted FSE sequences are superior to SSFP sequences in visualizing the biliary tree and pancreatic duct and that they should replace gradient-echo sequences in MR cholangiopancreatography.

Entities:  

Mesh:

Year:  1995        PMID: 7549198     DOI: 10.1002/jmri.1880050403

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Staging of Klatskin tumours (hilar cholangiocarcinomas): comparison of MR cholangiography, MR imaging, and endoscopic retrograde cholangiography.

Authors:  Thomas J Vogl; Wolfram O Schwarz; Matthias Heller; Christopher Herzog; Stephan Zangos; Rainer E Hintze; Peter Neuhaus; Renate M Hammerstingl
Journal:  Eur Radiol       Date:  2006-04-19       Impact factor: 5.315

Review 2.  Magnetic resonance cholangiopancreatography.

Authors:  P W Bearcroft; D J Lomas
Journal:  Gut       Date:  1997-08       Impact factor: 23.059

3.  Preoperative evaluation of the cystic duct for laparoscopic cholecystectomy: comparison of navigator-gated prospective acquisition correction- and conventional respiratory-triggered techniques at free-breathing 3D MR cholangiopancreatography.

Authors:  Ryo Itatani; Tomohiro Namimoto; Hiroo Kajihara; Akira Yoshimura; Kazuhiro Katahira; Jiro Nasu; Ikuo Matsushita; Fumi Sakamoto; Masafumi Kidoh; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-02-27       Impact factor: 5.315

4.  Evaluation of the biliary and pancreatic system with 2D SSFSE, breathhold 3D FRFSE and respiratory-triggered 3D FRFSE sequences.

Authors:  S Palmucci; L A Mauro; M Coppolino; A G Musumeci; P V Foti; P Milone; G C Ettorre
Journal:  Radiol Med       Date:  2010-01-15       Impact factor: 3.469

5.  Magnetic resonance cholangiopancreatography: Comparison of two- and three-dimensional sequences for the assessment of pancreatic cystic lesions.

Authors:  Kefu Liu; Ping Xie; Weijun Peng; Zhengrong Zhou
Journal:  Oncol Lett       Date:  2015-02-05       Impact factor: 2.967

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.