Literature DB >> 7548375

Comparison for four techniques of catheter insertion in patients undergoing continuous ambulatory peritoneal dialysis.

T L Hwang1, M F Chen, C H Wu, M L Leu, C C Huang.   

Abstract

OBJECTIVE: To compare four different ways of implanting catheters for continuous ambulatory peritoneal dialysis (CAPD) in an effort to reduce the incidence of complications.
DESIGN: Retrospective study.
SETTING: Teaching hospital, Taiwan.
SUBJECTS: 166 Patients who had 180 catheters inserted between 1985 and 1993.
INTERVENTIONS: 49 Catheters were inserted through midline incisions (in 24 of which the catheter was fixed with an additional suture) and 131 were inserted through paramedian incisions (in 88 of which the catheter was fixed with an additional suture). MAIN OUTCOME MEASURES: Morbidity, particularly the incidence of migration of the catheter and incisional hernia.
RESULTS: 8/68 Catheters migrated in patients in whom no additional fixing suture had been used, compared with 2/112 in whom an additional suture had been used (p = 0.007). There were 4 incisional hernias in 49 midline, compared with 0/131 paramedian, incisions (p < 0.0001). Significantly more catheters had to be removed after midline than after paramedian incisions (35/49 compared with 56/131, p = 0.0008); chi square for independence 15.02, df 3, p = 0.0018.
CONCLUSION: For the implantation of catheters for CAPD the paramedian incision is associated with significantly fewer complications than the midline incision and the incidence is even lower if the catheter is fixed to the lower peritoneum with an additional suture.

Entities:  

Mesh:

Year:  1995        PMID: 7548375

Source DB:  PubMed          Journal:  Eur J Surg        ISSN: 1102-4151


  4 in total

1.  The placement of peritoneal dialysis catheters: a prospective randomized comparison of open surgery versus "Mini-Perc" technique.

Authors:  Wei Zhu; Chunming Jiang; Xi Zheng; Miao Zhang; Hongqian Guo; Xiang Yan
Journal:  Int Urol Nephrol       Date:  2014-11-14       Impact factor: 2.370

2.  Comparison of open and laparoscopic secure placement of peritoneal dialysis catheters.

Authors:  P Soontrapornchai; T Simapatanapong
Journal:  Surg Endosc       Date:  2004-11-18       Impact factor: 4.584

3.  A modified open surgery technique for peritoneal dialysis catheter placement decreases catheter malfunction.

Authors:  Chunming Jiang; Linfeng Xu; Yun Chen; Xiang Yan; Cheng Sun; Miao Zhang
Journal:  Perit Dial Int       Date:  2014-06       Impact factor: 1.756

4.  Laparoscopic omental fixation technique versus open surgical placement of peritoneal dialysis catheters.

Authors:  G Oğünç; M Tuncer; D Oğünç; M Yardimsever; F Ersoy
Journal:  Surg Endosc       Date:  2003-06-19       Impact factor: 4.584

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.