Substitution of left ventricular outflow tract diameter with prosthesis size is inadequate for calculation of the aortic prosthetic valve area by the continuity equation.

P Pibarot1, G N Honos, L G Durand, J G Dumesnil.   

Abstract

It remains uncertain whether prosthetic ring size should be used interchangeably with measured left ventricular outflow tract (LVOT) diameter in the continuity equation to estimate the aortic prosthetic valve area by transthoracic Doppler echocardiography. To determine the difference in area caused by this substitution, the area of the prosthetic valve was calculated in 143 patients with aortic bioprostheses by use of the standard continuity equation with the measured LVOT diameter (LVOT method) and then with the bioprosthetic size (size method). Compared with known in vitro prosthetic valve areas, the LVOT method (r = 0.86; standard error of the estimate +/- 0.16 cm2; p < 0.001) was more accurate than the size method (r = 0.74; standard error of the estimate +/- 0.40 cm2; p < 0.001). The prosthetic valve area estimated by the size method overestimated the area estimated by the LVOT method by an average of 15% +/- 23% (p < 0.001). This difference in area between the two methods has increased with the interval since implantation of the bioprosthesis (p = 0.01). It is concluded that prosthetic size should not be used instead of LVOT diameter during calculation of aortic prosthetic valve area. This restriction is particularly important in patients with older bioprosthesis.

Entities:  

Mesh:

Year:  1995        PMID: 7546788     DOI: 10.1016/s0894-7317(05)80339-6

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

1.  Time-frequency analysis of heart murmurs. Part I: Parametric modelling and numerical simulations.

Authors:  F Debiais; L G Durand; P Pibarot; R Guardo
Journal:  Med Biol Eng Comput       Date:  1997-09       Impact factor: 2.602

2.  [Imaging following valve replacement].

Authors:  D Dabir; E Arroyo-Ucar; E A Ucar; E Nagel
Journal:  Radiologe       Date:  2013-10       Impact factor: 0.635

3.  High transvalvular pressure gradients on intraoperative transesophageal echocardiography after aortic valve replacement: what does it mean?

Authors:  A Parnell; J Swanevelder
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

Review 4.  Echocardiographic Assessment of Heart Valve Prostheses.

Authors:  Chiara Sordelli; Sergio Severino; Luigi Ascione; Pasquale Coppolino; Pio Caso
Journal:  J Cardiovasc Echogr       Date:  2014 Oct-Dec
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.