Literature DB >> 7546580

The use of expanded polytetrafluoroethylene (Gore-Tex) in rhinoplasty. A 6-year experience.

M S Godin1, S R Waldman, C M Johnson.   

Abstract

OBJECTIVE: To determine the safety and efficacy of expanded polytetrafluoroethylene (Gore-Tex soft-tissue patch, W. L. Gore & Assoc Inc, Flagstaff, Ariz) as an implant in rhinoplasty.
DESIGN: A retrospective study of 137 patients who underwent rhinoplasty including augmentation with Gore-Tex over a 6-year period. A review of the medical literature concerning the use of Gore-Tex as an implant in the head and neck was also conducted.
SETTING: Two major academic medical centers and two private office surgical centers. PARTICIPANTS: One hundred thirty-seven consecutive patients who received Gore-Tex implants in the course of rhinoplasty. INTERVENTION: Sixty-nine patients presented for primary rhinoplasty; the remaining 68 presented for revision surgery. All received Gore-Tex nasal implants to augment the nasal dorsum and/or base. The grafts ranged from 1 to 6 mm in thickness. Follow-up ranged from 6 to 80 months, with an average of 25 months. OUTCOME MEASURES: Clinically noted complications and patient satisfaction.
RESULTS: Three (2.2%) of 137 grafts became infected and were removed. One graft was removed 5 months post-operatively because of excessive augmentation. None of the patients who underwent implant removal required subsequent augmentation. All 137 patients are pleased with their results.
CONCLUSION: Gore-Tex is a safe and effective implant material to use in primary and revision rhinoplasty when augmentation is needed and autogenous material is not available or desirable.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7546580     DOI: 10.1001/archotol.1995.01890100043007

Source DB:  PubMed          Journal:  Arch Otolaryngol Head Neck Surg        ISSN: 0886-4470


  13 in total

1.  An overview of nasal dorsal augmentation.

Authors:  Harley S Dresner; Peter A Hilger
Journal:  Semin Plast Surg       Date:  2008-05       Impact factor: 2.314

2.  Alloplast as an alternative for dorsal augmentation.

Authors:  Thomas J Hubbard
Journal:  Semin Plast Surg       Date:  2008-05       Impact factor: 2.314

3.  An immobilized liquid interface prevents device associated bacterial infection in vivo.

Authors:  Jiaxuan Chen; Caitlin Howell; Carolyn A Haller; Madhukar S Patel; Perla Ayala; Katherine A Moravec; Erbin Dai; Liying Liu; Irini Sotiri; Michael Aizenberg; Joanna Aizenberg; Elliot L Chaikof
Journal:  Biomaterials       Date:  2016-09-30       Impact factor: 12.479

4.  Dual Plane Augmentation Genioplasty Using Gore-Tex Chin Implants.

Authors:  Byung Jun Kim; Jong Woo Lim; Ji Hoon Park; Yoon Ho Lee
Journal:  Arch Craniofac Surg       Date:  2014-08-14

5.  Dorsal augmentation with autogenous rib cartilage.

Authors:  Jack P Gunter; C Spencer Cochran; Vincent P Marin
Journal:  Semin Plast Surg       Date:  2008-05       Impact factor: 2.314

6.  Rib grafts in septorhinoplasty.

Authors:  A Moretti; S Sciuto
Journal:  Acta Otorhinolaryngol Ital       Date:  2013-06       Impact factor: 2.124

7.  Implants for reconstructive surgery of the nose and ears.

Authors:  Alexander Berghaus
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2008-03-14

8.  "Ride-on" technique and other simple and logical solutions to counter most common complications of silicone implants in augmentation rhinoplasty.

Authors:  Kapil S Agrawal; Manoj V Bachhav; Charudatta S Naik; Shikha Gupta; Anup V Sarda; Vyoma Desai
Journal:  Indian J Plast Surg       Date:  2015 May-Aug

9.  Histologic changes of implanted gore bio-a in an experimental animal model.

Authors:  Kwan Koo Yeo; Tae Hwan Park; Jin Hyuk Park; Choong Hyun Chang; June-Kyu Kim; Sang Won Seo
Journal:  Biomed Res Int       Date:  2014-05-21       Impact factor: 3.411

10.  Safety and Efficacy of Cosmetic Augmentation of the Nasal Tip and Nasal Dorsum With Expanded Polytetrafluoroethylene: A Randomized Clinical Trial.

Authors:  Yifei Gu; Wenxin Yu; Yunbo Jin; Hui Chen; Gang Ma; Shih-Jen Chang; Xiaoxi Lin
Journal:  JAMA Facial Plast Surg       Date:  2018-07-01       Impact factor: 4.611

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.