Literature DB >> 7541302

Diagnosis of early ectopic pregnancy by measurement of the maternal serum to cul-de-sac fluid beta-hCG ratio.

B Hinney1, C Bertagnoli, M Tobler-Sommer, R Osmers, W Wuttke, W Kuhn.   

Abstract

In patients suspected of having an ectopic pregnancy, because of a positive beta-human chorionic gonadotropin (beta-hCG) test and a sonographically undetectable gestational sac, even laparoscopy cannot always achieve a precise diagnosis, when the gestational age is very early. This means that the patient has to be followed by repeated beta-hCG measurements and repeated laparoscopy, which are expensive and inconvenient for the patient. This paper reports on a method that is simple to perform and that will provide the clinician with valuable information about the strong likelihood of a tubal pregnancy when ultrasound and beta-hCG measurements raise the suspicion but are not diagnostic. A prerequisite for this approach is the availability of a minimal volume (1-2 ml) of peritoneal fluid in the pouch of Douglas. A total of 131 patients who had a positive beta-hCG test and an undetectable gestational sac within the uterine cavity and who had a small volume of cul-de-sac fluid were studied. The fluid was obtained transvaginally by means of an ultrasound-guided automatic puncture system. The beta-hCG level was determined in the cul-de-sac fluid and in the maternal serum, for comparison. In two cases with tubal pregnancy, concentrated viscous blood samples were aspirated and beta-hCG concentrations could not be measured for technical reasons. In 129 cases, the ratio of levels of beta-hCG between serum and cul-de-sac fluid could be measured. In 42 out of 44 patients with intrauterine pregnancy, the ratio was greater than unity; in 82 out of 85 patients with a tubal pregnancy, the ratio was less than unity. With this ratio used for detection of tubal pregnancy, the diagnostic sensitivity of the test was 95.4% and the specificity was 95.2%. The positive predictive value was 97.6% and the negative predictive value 91.3%. We conclude from these findings that the measurement of the maternal serum to cul-de-sac fluid beta-hCG ratio facilitated the early diagnosis of an ectopic pregnancy in the Fallopian tube.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7541302     DOI: 10.1046/j.1469-0705.1995.05040260.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  2 in total

1.  The maternal plasma proteome changes as a function of gestational age in normal pregnancy: a longitudinal study.

Authors:  Roberto Romero; Offer Erez; Eli Maymon; Piya Chaemsaithong; Zhonghui Xu; Percy Pacora; Tinnakorn Chaiworapongsa; Bogdan Done; Sonia S Hassan; Adi L Tarca
Journal:  Am J Obstet Gynecol       Date:  2017-03-03       Impact factor: 8.661

2.  Human Chorionic Gonadotropine in Cul-de-sac Fluid in Tubal Ectopic Pregnacy; A New Diagnostic Approach.

Authors:  Ayse Karahasanoglu; Isil Uzun; Mucize Ozdemir; Fehmi Yazicioglu
Journal:  J Clin Diagn Res       Date:  2016-04-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.