OBJECTIVES: The clinical feasibility of self-expanding metal stents with respect to the technical success, complications, and reintervention rate should be tested.
METHODS: Five coated and 26 uncoated prototype Wallstents, especially designed for stenosis of the upper GI tract, were implanted in 23 patients. All patients with dysphagia suffered from inoperable tumor stenosis of the esophagus or the cardia. Stent implantation was performed under slight i.v. sedoanalgesia.
RESULTS: Technical success was achieved in all 31 implanted stents. Forty-eight hr after implantation, dysphagia was improved in 21/23 patients. Acute problems observed within 1 wk were stent migration (1 patient, uncoated stent), oblique position of the stent (3 patients), epigastric or retrosternal pain (9 patients), insufficient stent expansion (4 patients), and pouch formation at the upper rim of the stent (4 patients). An uncomplicated follow-up (median 66 days, range 10-139 days) was seen in 12 patients (52%). Major problems in the follow-up period were stent migration in three patients (three coated stents, two stent migrations in one patient) and stent obstruction by tumor ingrowth/overgrowth and/or food impaction in eight patients (35%). Most of these problems could be successfully resolved by implantation of a second stent or electrocoagulation of overgrowing tumor tissue. By the 1st of March, 1994, three patients were still alive with a follow-up period of 530 days (median range, 336-880 days); 20 patients were decreased with a follow-up period of 70 days (median range, 3-374 days).
CONCLUSIONS: Implantation of esophageal Wallstents is safe and has a low risk of acute complications and mortality for the patient. Early complications such as perforation and bleeding did not occur. Tumor ingrowth/overgrowth are the major reasons for the high reintervention rate in the follow-up period. Coated stents can resolve this problem, provided that stent migration can be avoided by improvement of the coating technology.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7521573

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  11 in total

Review 1.  Endoscopic management of esophageal leaks.

Authors:  Gabie K B Ong; Richard K Freeman
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

2.  Palliation of dysphagia from inoperable oesophageal carcinoma using Atkinson tubes or self-expanding metal stents.

Authors:  N Davies; H G Thomas; I A Eyre-Brook
Journal:  Ann R Coll Surg Engl       Date:  1998-11       Impact factor: 1.891

3.  Memory metal stents for palliation of malignant obstruction of the oesophagus and cardia.

Authors:  A May; M Selmaier; J Hochberger; L Gossner; S Mühldorfer; E G Hahn; C Ell
Journal:  Gut       Date:  1995-09       Impact factor: 23.059

4.  A rare life-threatening complication of migrated nitinol self-expanding metallic stent (Ultraflex).

Authors:  H S S Ho; H S Ong
Journal:  Surg Endosc       Date:  2004-02       Impact factor: 4.584

5.  Delayed complications after placement of self-expanding stents in malignant esophageal obstruction: treatment strategies and survival rate.

Authors:  Nils Homann; Maria R Noftz; Rolf D Klingenberg-Noftz; Diether Ludwig
Journal:  Dig Dis Sci       Date:  2007-06-28       Impact factor: 3.199

6.  Evidence-based choice of esophageal stent for the palliative management of malignant dysphagia.

Authors:  Danny Yakoub; Ramy Fahmy; Thanos Athanasiou; Afshin Alijani; Christopher Rao; Ara Darzi; George B Hanna
Journal:  World J Surg       Date:  2008-09       Impact factor: 3.352

7.  Self-expanding metal stents in palliation of malignant dysphagia: outcome of 124 Egyptian patients.

Authors:  Asser Abdel Raouf Elsharkawy; A A El-Geidie
Journal:  Eur Arch Otorhinolaryngol       Date:  2010-01-13       Impact factor: 2.503

8.  Small caliber covered self-expanding metal stents in the management of malignant dysphagia.

Authors:  Stephen Kucera; James Barthel; Jason Klapman; Ravi Shridhar; Sarah Hoffe; Cynthia Harris; Khaldoun Almhanna; Kenneth Meredith
Journal:  J Gastrointest Oncol       Date:  2016-06

9.  A randomised prospective comparison of the Flamingo Wallstent and Ultraflex stent for palliation of dysphagia associated with lower third oesophageal carcinoma.

Authors:  T Sabharwal; M S Hamady; S Chui; S Atkinson; R Mason; A Adam
Journal:  Gut       Date:  2003-07       Impact factor: 23.059

10.  Combined airway and esophageal stents implantation for malignant tracheobronchial and esophageal disease: A STROBE-compliant article.

Authors:  Yonghua Bi; Jianzhuang Ren; Hongmei Chen; Liangliang Bai; Xinwei Han; Gang Wu
Journal:  Medicine (Baltimore)       Date:  2019-01       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.