Literature DB >> 7519796

Confirmation of hepatitis C infection: a comparison of five immunoblot assays.

H L Zaaijer1, H Vrielink, P J van Exel-Oehlers, H T Cuypers, P N Lelie.   

Abstract

BACKGROUND: Recently, new immunoblot assays for the detection of antibodies to hepatitis C virus (HCV) became available. STUDY DESIGN AND METHODS: The performance of five confirmatory anti-HCV immunoblot assays was studied with samples with known HCV antibody and HCV RNA status. The assays were a third-generation strip recombinant immunoblot assay (RIBA-3, Chiron Corp., Emeryville, CA), a second-generation HCV blot (DB-2 blot, Diagnostic Biotechnology, Singapore), the Wellcozyme HCV Western blot (Murex blot, Murex Diagnostics, Dartford, UK), an immunodot HCV assay (Matrix, Abbott Laboratories, Chicago, IL), and the third-generation HCV line immunoassay (Liatek-III, Organon Teknika, Boxtel, The Netherlands).
RESULTS: Sensitivity on samples from 48 HCV RNA-positive, second-generation RIBA (RIBA-2)-positive persons and specificity on samples from 31 low-risk donors was 96 percent or better for all assays. The sensitivity on 31 HCV RNA-positive, RIBA-2-indeterminate samples was as follows: Liatek-III, 94 percent; RIBA-3, 90 percent; Murex blot, 61 percent; Matrix, 55 percent; and DB-2 blot, 39 percent. In testing 39 HCV RNA-negative, RIBA-2-indeterminate donor samples, the percentage found to be negative was Liatek-III, 77 percent; RIBA-3, 67 percent; Murex blot, 49 percent; DB-2 blot, 33 percent; and Matrix, 15 percent. The order of sensitivity on four HCV seroconversion series was (from high to low): RIBA-3, Liatek-III, DB-2 blot, Murex blot, and Matrix; the differences were small.
CONCLUSION: Detection of HCV antibodies was not refined by the addition of new HCV antigens (NS5, E2/NS1), but by improved classical antigens (core, NS3, NS4). Replacement of the commonly used RIBA-2 will resolve the status of a high proportion of RIBA-2-indeterminate samples.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7519796     DOI: 10.1046/j.1537-2995.1994.34794330015.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  1 in total

1.  Automated RIBA hepatitis C virus (HCV) strip immunoblot assay for reproducible HCV diagnosis.

Authors:  P Martin; F Fabrizi; V Dixit; S Quan; M Brezina; E Kaufman; K Sra; R DiNello; A Polito; G Gitnick
Journal:  J Clin Microbiol       Date:  1998-02       Impact factor: 5.948

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.