Literature DB >> 7514984

A dry electrode for EEG recording.

B A Taheri1, R T Knight, R L Smith.   

Abstract

This paper describes the design, fabrication and testing of a prototype dry surface electrode for EEG signal recording. The new dry electrode has the advantages of no need for skin preparation or conductive paste, potential for reduced sensitivity to motion artifacts and an enhanced signal-to-noise ratio. The electrode's sensing element is a 3 mm stainless steel disk which has a 2000 A (200 nm) thick nitride coating deposited onto one side. The back side of the disk is attached to an impedance converting amplifier. The prototype electrode was mounted on a copper plate attached to the scalp by a Velcro strap. The performance of this prototype dry electrode was compared to commercially available wet electrodes in 3 areas of electroencephalogram (EEG) recording: (1) spontaneous EEG, (2) sensory evoked potentials, and (3) cognitive evoked potentials. In addition to the raw EEG, the power spectra of the signals from both types of electrodes were also recorded. The results suggest that the dry electrode performs comparably to conventional electrodes for all types of EEG signal analysis. This new electrode may be useful for the production of high resolution surface maps of brain activity where a large number of electrodes or prolonged recording times are required.

Entities:  

Mesh:

Year:  1994        PMID: 7514984     DOI: 10.1016/0013-4694(94)90053-1

Source DB:  PubMed          Journal:  Electroencephalogr Clin Neurophysiol        ISSN: 0013-4694


  12 in total

Review 1.  Brain computer interfaces, a review.

Authors:  Luis Fernando Nicolas-Alonso; Jaime Gomez-Gil
Journal:  Sensors (Basel)       Date:  2012-01-31       Impact factor: 3.576

2.  Preparation and characterization of a novel sprayable hydrogel for skin preparation to record ECG and other biopotentials.

Authors:  Sunil Tej Boppudi; Suliman Belal; Sitaramanjaneya Reddy Guntur
Journal:  Biomed Eng Lett       Date:  2020-07-29

3.  Improvement of EEG signal acquisition: an electrical aspect for state of the art of front end.

Authors:  Ali Bulent Usakli
Journal:  Comput Intell Neurosci       Date:  2010-02-02

4.  Non-invasive computerized system for automatically initiating vagus nerve stimulation following patient-specific detection of seizures or epileptiform discharges.

Authors:  Ali Shoeb; Trudy Pang; John Guttag; Steven Schachter
Journal:  Int J Neural Syst       Date:  2009-06       Impact factor: 5.866

Review 5.  Wearable EEG and beyond.

Authors:  Alexander J Casson
Journal:  Biomed Eng Lett       Date:  2019-01-04

6.  Comparison of dry and gel based electrodes for p300 brain-computer interfaces.

Authors:  Christoph Guger; Gunther Krausz; Brendan Z Allison; Guenter Edlinger
Journal:  Front Neurosci       Date:  2012-05-07       Impact factor: 4.677

7.  A power-efficient bio-potential acquisition device with DS-MDE sensors for long-term healthcare monitoring applications.

Authors:  Chia-Lin Chang; Chih-Wei Chang; Hong-Yi Huang; Chen-Ming Hsu; Chia-Hsuan Huang; Jin-Chern Chiou; Ching-Hsing Luo
Journal:  Sensors (Basel)       Date:  2010-05-11       Impact factor: 3.576

8.  Exploring miniaturized EEG electrodes for brain-computer interfaces. An EEG you do not see?

Authors:  Martin G Bleichner; Micha Lundbeck; Matthias Selisky; Falk Minow; Manuela Jäger; Reiner Emkes; Stefan Debener; Maarten De Vos
Journal:  Physiol Rep       Date:  2015-04

9.  3D Printed Dry EEG Electrodes.

Authors:  Sammy Krachunov; Alexander J Casson
Journal:  Sensors (Basel)       Date:  2016-10-02       Impact factor: 3.576

Review 10.  A Review of Issues Related to Data Acquisition and Analysis in EEG/MEG Studies.

Authors:  Aina Puce; Matti S Hämäläinen
Journal:  Brain Sci       Date:  2017-05-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.