Comparison of ventricular function in atrial rate adaptive versus dual chamber rate adaptive pacing during exercise.

D M Gallik1, G W Guidry, J J Mahmarian, M S Verani, W H Spencer.   

Abstract

The hemodynamic effects of two different pacing modes--rate adaptive atrial (AAIR) versus dual chamber (DDDR) pacing--were assessed in 12 patients with DDDR pacemakers during upright bicycle exercise first-pass radionuclide angiography using a multiwire gamma camera with tantalum-178 as a tracer. All patients had sinus node disease with intact AV conduction. Patients exercised to the same heart rate in random order in these two different pacing modes, AAIR and DDDR with AV delay (of 100 msec) selected to maintain 100% ventricular capture. Cardiac output increased significantly above baseline values during exercise in both pacing modes: 154 +/- 41% (mean +/- SEM, P = 0.002) with AAIR, versus 95 +/- 24% (P = 0.004) with DDDR (P = NS between the two modes). The peak filling rate, likewise, increased in both pacing modes (2.3 +/- 0.21 end-diastolic volumes/sec to 3.8 +/- 0.31 end-diastolic volumes/sec in AAIR [P = 0.0004] and 2.2 +/- 0.18 end-diastolic volumes/sec to 3.4 +/- 0.27 end-diastolic volumes/sec in DDDR [P = 0.0008]). LV ejection fraction was normal at rest (60 +/- 4%, SEM) and did not significantly change with submaximal exercise in either pacing mode (both 56%, P = NS). No significant changes in end-diastolic volume or stroke volume indexes occurred with exercise in either pacing mode. Our study demonstrates that in patients with normal resting LV function, AAIR and DDDR pacing are equally effective in attaining appropriate increases in cardiac output and LV filling during exercise.

Entities:  

Mesh:

Year:  1994        PMID: 7513403     DOI: 10.1111/j.1540-8159.1994.tb01370.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Non-physiological increase of AV conduction time in sinus disease patients programmed in AAIR-based pacing mode.

Authors:  Philippe Mabo; Jean-Pierre Cebron; Aude Solnon; Aude Tassin; Laurence Graindorge; Daniel Gras
Journal:  J Interv Card Electrophysiol       Date:  2012-07-27       Impact factor: 1.900

Review 2.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004