Literature DB >> 750199

The bedside determination of extravascular lung water: a non-invasive double indicator technique using 123I-antipyrine, 113mIn-transferrin and external counting.

R O Binswanger, H Rösler, U Noelpp, L Matter, M Haertel.   

Abstract

Using the formulae of Fazio and coworkers, we calculated the extravascular lung water per unit of blood volume (ELW/V) and per unit of blood flow (ELW/F) after intravenous injection of 113In-transferrin as the blood label, and 123I-antipyrine as the diffusible, i.e. water label. Time-activity curves were recorded over the right anterior upper chest wall using a mobile detector. The curves were digitalized and fitted to a gamma-variate using a GAMMA-11 computer. Area over height calculations gave the mean transit times (t). Sixteen control subjects, without evidence of cardiac or pulmonary disease, and 10 patients, with clinical and radiological evidence of left heart failure, were examined. In the control group ELW/V was 0.37 plus or minus 0.17 and ELW/F 3.39 plus or minus 1.56 (mean plus or minus 1 SD). In the patients ELW/V was 0.71 plus or minus 0.26 and ELW/F 13.10 plus or minus 5.67. The difference between both ELW/V and ELW/F for the control group and the patient group is statistically significant. Our values for ELW/V both in patients and control subjects are very similar to those obtained by Fazio and coworkers using H2 15O. However, our values for ELW/F differed from those of Fazio; this could be partly due to dependence of this parameter on the cardiac output.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 750199     DOI: 10.1007/bf00251634

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  9 in total

1.  Estimation of extravascular lung water by indicator-dilution techniques.

Authors:  F P Chinard
Journal:  Circ Res       Date:  1975-08       Impact factor: 17.367

2.  INDICATOR TRANSIT TIME CONSIDERED AS A GAMMA VARIATE.

Authors:  H K THOMPSON; C F STARMER; R E WHALEN; H D MCINTOSH
Journal:  Circ Res       Date:  1964-06       Impact factor: 17.367

3.  Transcapillary pulmonary exchange of water in the dog.

Authors:  F P CHINARD; T ENNS
Journal:  Am J Physiol       Date:  1954-08

4.  Impairment of red cell transit through the canine lungs following injections of hypertonic fluids.

Authors:  R M Effros
Journal:  Circ Res       Date:  1972-10       Impact factor: 17.367

5.  Quantitative assessment of pulmonary edema.

Authors:  O R Levine; R B Mellins; A P Fishman
Journal:  Circ Res       Date:  1965-11       Impact factor: 17.367

6.  Lung water in congestive heart failure.

Authors:  P N Yu
Journal:  Mod Concepts Cardiovasc Dis       Date:  1971-06

7.  Absorbed dose calculations for 113mIn placental scanning.

Authors:  E J van der Merwe; M G Lotter; P D van Heerden; C F Slabber; J Bester
Journal:  J Nucl Med       Date:  1970-01       Impact factor: 10.057

8.  Measurement of regional pulmonary oedema in man using radioactive water (H215O).

Authors:  F Fazio; T Jones; C G MacArthur; C G Rhodes; R E Steiner; J M Hughes
Journal:  Br J Radiol       Date:  1976-05       Impact factor: 3.039

9.  Nontraumatic assessment of left ventricular wall motion and regional stroke volume after myocardial infarction.

Authors:  N Schad
Journal:  J Nucl Med       Date:  1977-04       Impact factor: 10.057

  9 in total
  4 in total

1.  Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method.

Authors:  H Almquist; J Palmer; M Ljungberg; P Wollmer; S E Strand; B Jonson
Journal:  Eur J Nucl Med       Date:  1990

2.  Lung water measurements with iodo-antipyrine.

Authors:  R Y Chu; P V Carlile; B A Gray; E W Allen; G Basmadjian; J Myers
Journal:  Eur J Nucl Med       Date:  1988

Review 3.  The impact of W. K. Röntgen's discovery on the use of internalizable sources of ionizing energy in diagnostic and therapeutic nuclear medicine.

Authors:  H Rösler
Journal:  Experientia       Date:  1995-07-14

4.  Quantification of regional extravascular lung water in dogs with positron emission tomography, using constant infusion of 15O-labeled water.

Authors:  G J Meyer; O Schober; C Bossaller; J Sturm; H Hundeshagen
Journal:  Eur J Nucl Med       Date:  1984
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.