Literature DB >> 7498917

Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression.

S C Pei1, C C Tseng.   

Abstract

In this paper, a technique for suppressing the transient states of IIR notch filter is investigated. This technique uses the vector projection to find better initial values for notch filters. When a notch or comb filter is used to eliminate power line (AC) interference in the recording of electrocardiograms (ECG), the performance of the notch filter with transient suppression is better than that of the conventional notch filter with arbitrary initial condition. The improvements with this technique are at the cost of additional computation load at the beginning of filtering.

Mesh:

Year:  1995        PMID: 7498917     DOI: 10.1109/10.469385

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Beat-to-beat noise removal in non-invasive His-bundle electrocardiogram.

Authors:  A Bazhyna; A Gotchev; I I Christov; I K Daskalov; K Egiazarian
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

2.  Removal of power-line interference from the ECG: a review of the subtraction procedure.

Authors:  Chavdar Levkov; Georgy Mihov; Ratcho Ivanov; Ivan Daskalov; Ivaylo Christov; Ivan Dotsinsky
Journal:  Biomed Eng Online       Date:  2005-08-23       Impact factor: 2.819

3.  Blockwise PPG Enhancement Based on Time-Variant Zero-Phase Harmonic Notch Filtering.

Authors:  Chanki Park; Hyunsoon Shin; Boreom Lee
Journal:  Sensors (Basel)       Date:  2017-04-14       Impact factor: 3.576

4.  A Real-Time Wearable Physiological Monitoring System for Home-Based Healthcare Applications.

Authors:  Jin-Woo Jeong; Woochan Lee; Young-Joon Kim
Journal:  Sensors (Basel)       Date:  2021-12-24       Impact factor: 3.576

5.  A hybrid approach to the simultaneous eliminating of power-line interference and associated ringing artifacts in electrocardiograms.

Authors:  Xiaolin Zhou; Yuanting Zhang
Journal:  Biomed Eng Online       Date:  2013-05-14       Impact factor: 2.819

Review 6.  Fetal ECG extraction from abdominal signals: a review on suppression of fundamental power line interference component and its harmonics.

Authors:  Dragoş-Daniel Ţarălungă; Georgeta-Mihaela Ungureanu; Ilinca Gussi; Rodica Strungaru; Werner Wolf
Journal:  Comput Math Methods Med       Date:  2014-02-09       Impact factor: 2.238

7.  SVD-Based Technique for Interference Cancellation and Noise Reduction in NMR Measurement of Time-Dependent Magnetic Fields.

Authors:  Wenjun Chen; Hong Ma; De Yu; Hua Zhang
Journal:  Sensors (Basel)       Date:  2016-03-04       Impact factor: 3.576

  7 in total