Literature DB >> 7498589

Dynamic mechanical analysis of two crosslinked copolymer systems.

K Tamareselvy1, F A Rueggeberg.   

Abstract

OBJECTIVES: This research investigated the dynamic mechanical properties of two model dental restorative copolymers to elucidate the influence of pendent group length and addition of crosslinking agent.
METHODS: Two different monomethacrylate resins [(methyl methacrylate (MMA) or 2-ethoxyethylmethacrylate (EEM)] were added to various molar fractions (0, 5, 10, 20, 40, 60, 80 and 100%) of a difunctional monomer [triethylene glycol dimethacrylate (TEGDMA)], resulting in two different copolymer systems (TMMA and TEEM). Bar-shaped specimens were heat-cured and tested for their dynamic mechanical properties at a fixed frequency (1Hz): flexural storage modulus and loss factor. Transition temperatures associated with peaks were determined using tan delta, phase angle and loss factor. The properties of one specimen were also examined using a range of applied frequencies.
RESULTS: Below the Tg, all resin systems had similar storage moduli. An increase in pendent group length lowered transition temperatures and demonstrated greater influence on temperature changes than did a change in crosslinker content. With increasing crosslinker, the transition temperatures increased. The values ascribed to transition temperatures were dependent upon the analysis method used: tan delta gave highest values, followed by phase angle, with loss factor values the lowest. Storage and loss moduli values and their ratio increased with increasing frequency of applied signal. Loss factor analysis provided the most elucidation of sub-Tg transitions. SIGNIFICANCE: Restorative polymers with specific desired physical and mechanical properties can be achieved by both judicious selection of monomer structure as well as by the controlled addition of the crosslinking agent.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7498589     DOI: 10.1016/0109-5641(94)90036-1

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  4 in total

1.  Comparative Evaluation of Bulk-Fill Composite Resins: Knoop Microhardness, Diametral Tensile Strength and Degree of Conversion.

Authors:  Bruna Scarcello Strini; Joyce Figueiredo de Lima Marques; Renata Pereira; Danielle Ferreira Sobral-Souza; Vanessa Gallego Arias Pecorari; Priscila Christiane Suzy Liporoni; Flávio Henrique Baggio Aguiar
Journal:  Clin Cosmet Investig Dent       Date:  2022-08-04

2.  Effect of crosslinking on the physicochemical properties of polydimethylsiloxane-based levonorgestrel intrauterine systems.

Authors:  Suraj Fanse; Quanying Bao; Yuan Zou; Yan Wang; Diane J Burgess
Journal:  Int J Pharm       Date:  2021-10-16       Impact factor: 6.510

3.  Investigation of flexural strength and cytotoxicity of acrylic resin copolymers by using different polymerization methods.

Authors:  Onur Sahin; Ali Kemal Ozdemir; Mehmet Turgut; Ali Boztug; Zeynep Sumer
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

4.  Comparison of variation in the light curing cycle with a time gap and its effect on polymerization shrinkage, degree of conversion and microhardness of a nanohybrid composite.

Authors:  Arunajatesan Subbiya; Newbegin Selvakumar Gold Pearlin Mary; Malathi Suresh; Paramasivam Vivekanandhan; Malarvizhi Dhakshinamoorthy; Vridhachalam Ganapathy Sukumaran
Journal:  J Conserv Dent       Date:  2015 Mar-Apr
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.