Literature DB >> 7497665

Screw osteolysis after cementless total knee replacement.

P L Lewis1, C H Rorabeck, R B Bourne.   

Abstract

A comparative radiographic review of 217 cementless total knee replacements was done 4 years after surgery to look for radiographic change at the screw-bone interface. There were 102 Miller Galante I knee prostheses, 59 Miller Galante II prostheses, and 56 Anatomic Modular Knee prostheses studied. If the appearance of the screw-bone interface had changed, this was classified according to the width of the lucency. Two hundred sixty-five of the 851 screws that were studied showed some evidence of change, with 185 (21.7%) of the screws showing a cavitary appearance change. The AMK prosthesis showed the higher incidence of cystic and cavitary changes. Polyethylene debris is thought to be responsible for generation of osteolysis and the radiographic appearance change. Design of the components and particularly the polyethylene attachment mechanisms may be responsible for the differences in the frequencies of osteolysis.

Entities:  

Mesh:

Year:  1995        PMID: 7497665

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Modular versus nonmodular tibial inserts in total knee arthroplasty: what are the differences?

Authors:  Asim M Makhdom; Javad Parvizi
Journal:  Ann Transl Med       Date:  2017-05

2.  Similar survival between screw cementless and cemented tibial components in young patients with osteoarthritis.

Authors:  Alejandro Lizaur-Utrilla; Francisco A Miralles-Muñoz; Fernando A Lopez-Prats
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-08       Impact factor: 4.342

3.  Disengagement of tibial insert locking pin in total knee arthroplasty - A rare failure case report.

Authors:  Sanjeev Jindal; Vivek Bansal; Mannan Ahmed
Journal:  J Clin Orthop Trauma       Date:  2022-08-21

4.  Treatment for Wear and Osteolysis in Well-Fixed Uncemented TKR.

Authors:  Leah Nunez; Brandon Broome; Tom Pace; Melinda Harman
Journal:  ISRN Orthop       Date:  2013-02-11

5.  A rare case of bilateral large osteolysis following cemented and cementless total knee arthroplasties.

Authors:  Julian Dexel; Stephan Kirschner; Melinda K Harman; Jörg Lützner
Journal:  Acta Orthop       Date:  2012-12-17       Impact factor: 3.717

6.  Total knee replacement-cementless tibial fixation with screws: 10-year results.

Authors:  Önder Ersan; Alper Öztürk; Mehmet Faruk Çatma; Serhan Ünlü; Mutlu Akdoğan; Yalım Ateş
Journal:  Acta Orthop Traumatol Turc       Date:  2017-11-01       Impact factor: 1.511

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.