Cobas Integra: clinical laboratory instrument with continuous and random-access capabilities.

S M Palmer1, R A Kaufman, S J Salamone, J Blake-Courtney, W Bette, H P Wahl, F Furrer.   

Abstract

The Cobas Integra from Roche Diagnostic Systems is a new clinical laboratory analyzer with continuous and random-access features for routine chemistries, specific proteins, electrolytes, hormones, therapeutic drugs, and drugs of abuse. The system maintains 68 test-specific reagent cassettes on board, along with multiple ion-selective electrodes (ISEs) for electrolyte determinations. This gives the Cobas Integra the capability of analyzing as many as 72 analytes without having to load additional reagents. We describe the basic analyzer configuration and the subsystems for absorbance, fluorescence polarization, and ISE measurements. Performance characteristics for precision, methods comparison, and on-board stability are given for assays representative of the various test groups. The 29 Cobas Integra tests evaluated in the present study show good agreement (r > or = 0.98 and slopes generally 0.90 to 1.12) with the respective methods available on either the Olympus AU5000, Hitachi 911 or 717, Behring BNA, or Abbott TDx systems. Total assay precision (CV) ranged from 0.8% to 8.5%, and calibration curves were stable for as long as 20 weeks. Test throughput, which is dependent on pipetting sequence, was determined to be up to 600 tests per hour without ISE and up to 750 tests per hour with ISE; the time to first result was 2.0-10.0 min.

Mesh:

Year:  1995        PMID: 7497616

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  Optimising assay sequence on automated coagulation instrumentation.

Authors:  T Givens; C Hunley; T Fischer; R Bowling
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

2.  Supra-therapeutic plasma concentrations of haloperidol induce moderate inhibition of lipopolysaccharide-induced interleukin-8 release in human monocytes.

Authors:  Herbert Bosshart
Journal:  Ann Transl Med       Date:  2016-10

3.  Hyponatremia as a prognostic and predictive factor in metastatic renal cell carcinoma.

Authors:  A N Jeppesen; H K Jensen; F Donskov; N Marcussen; H von der Maase
Journal:  Br J Cancer       Date:  2010-02-09       Impact factor: 7.640

4.  Biochemical effects and safety of Gum arabic (Acacia Senegal) supplementation in patients with sickle cell anemia.

Authors:  Lamis AbdelGadir Kaddam; Imad Fdl-Elmula; Omer Ali Eisawi; Haydar Awad Abdelrazig; Mustafa Khidir Elnimeiri; Amal Mahmoud Saeed
Journal:  Blood Res       Date:  2019-03-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.