Literature DB >> 7496951

Effect of specimen storage on absolute CD4 counts.

S Kabengera1, D Hom, B Jackson.   

Abstract

We have evaluated the effect of specimen storage on absolute CD4 counts by a commercially available manual assay. This assay utilizes latex particles coated with CD4 monoclonal antibodies that are mixed with lymphocytes in whole blood. Thirty blood samples were analyzed on days 1, 2, 4, and 7 postcollection. Linear regression analysis and Pearson correlation coefficients were used to determine the relationship between the absolute CD4 count and the storage time after sample collection. There was a significant decrease in absolute CD4 counts from baseline over time, dropping 3.6% at day 2, 10.1% at day 4, and 18.8% at day 7. However, the standard error of the B coefficient was constant [SE (B) = 0.031] up to day 4, indicating that reliable estimates of the baseline CD4 counts could be made from the CD4 counts determined up to day 4 from the time of sample collection. In addition to being sample, rapid, and inexpensive, the manual assay is capable of giving a reliable absolute CD4 count after specimen storage of up to 4 days. The application of this assay in the limited facilities of developing countries' laboratories is attractive.

Entities:  

Mesh:

Year:  1994        PMID: 7496951      PMCID: PMC368233          DOI: 10.1128/cdli.1.2.232-234.1994

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  3 in total

1.  Serial CD4 lymphocyte counts and development of AIDS.

Authors:  A N Phillips; C A Lee; J Elford; G Janossy; A Timms; M Bofill; P B Kernoff
Journal:  Lancet       Date:  1991-02-16       Impact factor: 79.321

Review 2.  CD4+ lymphocyte cell enumeration for prediction of clinical course of human immunodeficiency virus disease: a review.

Authors:  D S Stein; J A Korvick; S H Vermund
Journal:  J Infect Dis       Date:  1992-02       Impact factor: 5.226

3.  A rapid manual method for CD4+ T-cell quantitation for use in developing countries.

Authors:  A Landay; J L Ho; D Hom; T Russell; R Zwerner; J G Minuty; P Kataaha; F Mmiro; B Jackson
Journal:  AIDS       Date:  1993-12       Impact factor: 4.177

  3 in total
  1 in total

1.  Detection of human immunodeficiency virus type 1 (HIV-1) DNA and RNA sequences in HIV-1 antibody-positive blood donors in Uganda by the Roche AMPLICOR assay.

Authors:  J B Jackson; E M Piwowar; J Parsons; P Kataaha; G Bihibwa; J Onecan; S Kabengera; S D Kennedy; A Butcher
Journal:  J Clin Microbiol       Date:  1997-04       Impact factor: 5.948

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.