Literature DB >> 7496699

The impact of digital imaging on patient doses during barium studies.

D A Broadhead1, C L Chapple, K Faulkner.   

Abstract

Barium studies performed on 10 digital and four non-digital fluoroscopic systems were monitored with dose-area product meters as part of a Regional Patient Dosimetry Audit programme. The data have been collected using a computer to read and reset the dose-area product meter and also to collect patient and examination details. A comparison of dose-area product measurements from digital and non-digital fluoroscopy units on over 10,000 barium studies is presented. The data have been corrected according to patient size. The mean size corrected dose-area product for a barium meal examination was found to be 7.62 Gy cm2 for a digital set compared with 15.45 Gy cm2 for a non-digital set with 2462 and 1308 patients included in each measurement series, respectively. Dose-area products were also a factor of approximately two lower for barium enema, barium swallow and barium follow-through examinations performed on digital systems.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7496699     DOI: 10.1259/0007-1285-68-813-992

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

2.  Scintigraphic evaluation of Zenker's diverticulum.

Authors:  Venanzio Valenza; Germano Perotti; Daniela Di Giuda; Gioacchino Castrucci; Giuseppe Celi; Gennaro Restaino
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-09       Impact factor: 9.236

3.  Optimization and audit of radiation dose during percutaneous transluminal coronary angioplasty.

Authors:  Roshan S Livingstone; B S Timothy Peace; Sunil Chandy; Paul V George; Purendra Pati
Journal:  J Med Phys       Date:  2007-10

4.  Evaluation of 18F-2-deoxy-2-fluoro-glucose positron emission tomography for gastric cancer screening in asymptomatic individuals undergoing endoscopy.

Authors:  H Shoda; Y Kakugawa; D Saito; T Kozu; T Terauchi; H Daisaki; C Hamashima; Y Muramatsu; N Moriyama; H Saito
Journal:  Br J Cancer       Date:  2007-11-27       Impact factor: 7.640

5.  Transition from image intensifier to flat panel detector in interventional cardiology: Impact of radiation dose.

Authors:  Roshan S Livingstone; David Chase; Anna Varghese; Paul V George; Oommen K George
Journal:  J Med Phys       Date:  2015 Jan-Mar

6.  Comparing ovarian radiation doses in flat-panel and conventional angiography during uterine artery embolization: a randomized clinical trial.

Authors:  Kavous Firouznia; Hossein Ghanaati; Aliakbar Sharafi; Firouze Abahashemi; Hassan Hashemi; Amir Hossein Jalali; Madjid Shakiba
Journal:  Iran J Radiol       Date:  2013-08-30       Impact factor: 0.212

  6 in total