Literature DB >> 7494875

Comparative assessment of single-dose and fractionated boron neutron capture therapy.

J A Coderre1, G M Morris, P L Micca, C D Fisher, G A Ross.   

Abstract

The effects of fractionating boron neutron capture therapy (BNCT) were evaluated in the intracerebral rat 9L gliosarcoma and rat spinal cord models using the Brookhaven Medical Research Reactor (BMRR) thermal neutron beam. The amino acid analog p-boronophenylalanine (BPA) was administered prior to each exposure to the thermal neutron beam. The total physical absorbed dose to the tumor during BNCT using BPA was 91% high-linear energy transfer (LET) radiation. Two tumor doses of 5.1 Gy spaced 48 h apart (n = 14) or three tumor doses of 5.2 Gy, each separated by 48 h (n = 10), produced 43 and 70% long-term (> 1 year) survivors, respectively [corrected]. The outcome of neither the two nor the three fractions of radiation was statistically different from that of the corresponding single-fraction group. In the rat spinal cord, the ED50 for radiation myelopathy (as indicated by limb paralysis within 7 months) after exposure to the thermal beam alone was 13.6 +/- 0.4 Gy. Dividing the beam-only irradiation into two or four consecutive daily fractions increased the ED50 to 14.7 +/- 0.2 Gy and 15.5 +/- 0.4 Gy, respectively. Thermal neutron irradiation in the presence of BPA resulted in an ED50 for myelopathy of 13.8 +/- 0.6 Gy after a single fraction and 14.9 +/- 0.9 Gy after two fractions. An increase in the number of fractions to four resulted in an ED50 of 14.3 +/- 0.6 Gy. The total physical absorbed dose to the blood in the vasculature of the spinal cord during BNCT using BPA was 80% high-LET radiation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7494875

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  10 in total

Review 1.  A review: CNS effects and normal tissue tolerance in dogs.

Authors:  P R Gavin; S L Kraft; R Huiskamp; J A Coderre
Journal:  J Neurooncol       Date:  1997-05       Impact factor: 4.130

2.  Boron neutron capture therapy: effects of split dose and overall treatment time.

Authors:  G M Morris; P L Micca; M Rezvani; J W Hopewell; J A Coderre
Journal:  J Neurooncol       Date:  2001-04       Impact factor: 4.130

3.  Boron neutron capture therapy for newly diagnosed glioblastoma multiforme: an assessment of clinical potential.

Authors:  K Sköld; T Gorlia; L Pellettieri; V Giusti; B H-Stenstam; J W Hopewell
Journal:  Br J Radiol       Date:  2010-07       Impact factor: 3.039

4.  Determining a methodology of dosimetric quality assurance for commercially available accelerator-based boron neutron capture therapy system.

Authors:  Katsumi Hirose; Takahiro Kato; Takaomi Harada; Tomoaki Motoyanagi; Hiroki Tanaka; Akihiko Takeuchi; Ryohei Kato; Shinya Komori; Yuhei Yamazaki; Kazuhiro Arai; Noriyuki Kadoya; Mariko Sato; Yoshihiro Takai
Journal:  J Radiat Res       Date:  2022-07-19       Impact factor: 2.438

Review 5.  Rat brain tumor models to assess the efficacy of boron neutron capture therapy: a critical evaluation.

Authors:  Rolf F Barth; Weilian Yang; Jeffrey A Coderre
Journal:  J Neurooncol       Date:  2003 Mar-Apr       Impact factor: 4.130

6.  Central nervous system tolerance to boron neutron capture therapy with p-boronophenylalanine.

Authors:  G M Morris; J A Coderre; P L Micca; C D Fisher; J Capala; J W Hopewell
Journal:  Br J Cancer       Date:  1997       Impact factor: 7.640

7.  Profile analysis of adverse events after boron neutron capture therapy for head and neck cancer: a sub-analysis of the JHN002 study.

Authors:  Katsumi Hirose; Mariko Sato; Takahiro Kato; Kanako Takayama; Motohisa Suzuki; Hisashi Yamaguchi; Ichiro Seto; Yasuhiro Kikuchi; Masao Murakami; Yoshihiro Takai
Journal:  J Radiat Res       Date:  2022-05-18       Impact factor: 2.438

8.  Improvement in the neutron beam collimation for application in boron neutron capture therapy of the head and neck region.

Authors:  Naonori Hu; Hiroki Tanaka; Ryo Kakino; Syuushi Yoshikawa; Mamoru Miyao; Kazuhiko Akita; Teruhito Aihara; Keiji Nihei; Koji Ono
Journal:  Sci Rep       Date:  2022-08-12       Impact factor: 4.996

9.  Comprehensive evaluation of dosimetric impact against position errors in accelerator-based BNCT under different treatment parameter settings.

Authors:  Ryo Kakino; Naonori Hu; Kayako Isohashi; Teruhito Aihara; Keiji Nihei; Koji Ono
Journal:  Med Phys       Date:  2022-07-04       Impact factor: 4.506

10.  Evaluation of a treatment planning system developed for clinical boron neutron capture therapy and validation against an independent Monte Carlo dose calculation system.

Authors:  Naonori Hu; Hiroki Tanaka; Ryo Kakino; Syuushi Yoshikawa; Mamoru Miyao; Kazuhiko Akita; Kayako Isohashi; Teruhito Aihara; Keiji Nihei; Koji Ono
Journal:  Radiat Oncol       Date:  2021-12-24       Impact factor: 3.481

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.