Literature DB >> 7494065

Comparison of recovery rates for mycobacteria from BACTEC 12B vials, Middlebrook 7H11-selective 7H11 biplates, and Lowenstein Jensen slants in a public health mycobacteriology laboratory.

M L Wilson1, B L Stone, M V Hildred, R R Reves.   

Abstract

Recovery rates from Middlebrook 7H11-selective 7H11 biplates and Lowenstein-Jensen slants (LJ) used with BACTEC 12B vials were compared for 5,399 specimens. For 578 specimens that were inoculated onto three media, 580 mycobacteria were isolated, including 277 (48%) Mycobacterium avium complex isolates, 230 (40%) Mycobacterium tuberculosis isolates, and 73 (12%) other mycobacteria. For BACTEC 12B vials, 506 (87%) cultures were positive, 45 (8%) were negative, and 29 (5%) were lost to contamination; for 7H11-7H11-selective biplates, 469 (81%) cultures were positive, 95 (16%) were negative, and 16 (3%) were lost to contamination; for LJ, 230 (40%) cultures were positive, 111 (19%) were negative, and 239 (41%) were lost to contamination. For routine cultures, use of plate media is superior to use of LJ.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7494065      PMCID: PMC228464          DOI: 10.1128/jcm.33.9.2516-2518.1995

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  7 in total

1.  Collaborative feasibility study of a biphasic system (Roche Septi-Chek AFB) for rapid detection and isolation of mycobacteria.

Authors:  H D Isenberg; R F D'Amato; L Heifets; P R Murray; M Scardamaglia; M C Jacobs; P Alperstein; A Niles
Journal:  J Clin Microbiol       Date:  1991-08       Impact factor: 5.948

2.  Comparison of improved BACTEC and Lowenstein-Jensen media for culture of mycobacteria from clinical specimens.

Authors:  P Anargyros; D S Astill; I S Lim
Journal:  J Clin Microbiol       Date:  1990-06       Impact factor: 5.948

3.  Rapid recovery of mycobacteria from clinical specimens using automated radiometric technic.

Authors:  C H Park; D L Hixon; C B Ferguson; S L Hall; C C Risheim; C B Cook
Journal:  Am J Clin Pathol       Date:  1984-03       Impact factor: 2.493

4.  Evaluation of the BACTEC radiometric method for recovery of mycobacteria and drug susceptibility testing of Mycobacterium tuberculosis from acid-fast smear-positive specimens.

Authors:  G D Roberts; N L Goodman; L Heifets; H W Larsh; T H Lindner; J K McClatchy; M R McGinnis; S H Siddiqi; P Wright
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

5.  Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens.

Authors:  M A Morgan; C D Horstmeier; D R DeYoung; G D Roberts
Journal:  J Clin Microbiol       Date:  1983-08       Impact factor: 5.948

6.  Role of solid media when used in conjunction with the BACTEC system for mycobacterial isolation and identification.

Authors:  C E Stager; J P Libonati; S H Siddiqi; J R Davis; N M Hooper; J F Baker; M E Carter
Journal:  J Clin Microbiol       Date:  1991-01       Impact factor: 5.948

Review 7.  Disease due to the Mycobacterium avium complex in patients infected with human immunodeficiency virus: diagnosis and susceptibility testing.

Authors:  G L Woods
Journal:  Clin Infect Dis       Date:  1994-04       Impact factor: 9.079

  7 in total
  14 in total

1.  Management of opportunist mycobacterial infections: Joint Tuberculosis Committee Guidelines 1999. Subcommittee of the Joint Tuberculosis Committee of the British Thoracic Society.

Authors: 
Journal:  Thorax       Date:  2000-03       Impact factor: 9.139

2.  Rapid detection of mycobacteria in clinical specimens by using the automated BACTEC 9000 MB system and comparison with radiometric and solid-culture systems.

Authors:  G E Pfyffer; C Cieslak; H M Welscher; P Kissling; S Rüsch-Gerdes
Journal:  J Clin Microbiol       Date:  1997-09       Impact factor: 5.948

3.  Mycobacterium and Aerobic Actinomycete Culture: Are Two Medium Types and Extended Incubation Times Necessary?

Authors:  Patricia J Simner; Kelly A Doerr; Lory K Steinmetz; Nancy L Wengenack
Journal:  J Clin Microbiol       Date:  2016-02-10       Impact factor: 5.948

4.  The diagnostic yield of acid-fast-bacillus smear-positive sputum specimens.

Authors:  B L Stone; W J Burman; M V Hildred; E A Jarboe; R R Reves; M L Wilson
Journal:  J Clin Microbiol       Date:  1997-04       Impact factor: 5.948

5.  Evaluation of a commercial radiometric system for primary isolation of mycobacteria over a fifteen-year period.

Authors:  A M Middleton; M V Chadwick; H Gaya
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1997-02       Impact factor: 3.267

6.  Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria.

Authors:  A J van Griethuysen; A R Jansz; A G Buiting
Journal:  J Clin Microbiol       Date:  1996-10       Impact factor: 5.948

7.  Extrapulmonary tuberculosis: an unusual presentation in an immunocompetent patient.

Authors:  Rosa Lombardi; Serena Pelusi; Lorena Airaghi; Silvia Fargion
Journal:  BMJ Case Rep       Date:  2015-05-06

8.  Increased sensitivity of the BACTEC 460 mycobacterial radiometric broth culture system does not decrease the number of respiratory specimens required for a definitive diagnosis of pulmonary tuberculosis.

Authors:  J D Harvell; W K Hadley; V L Ng
Journal:  J Clin Microbiol       Date:  2000-10       Impact factor: 5.948

9.  Comparison of the Lowenstein-Jensen Medium, the Middlebrook 7H10 Medium and MB/BacT for the Isolation of Mycobacterium Tuberculosis (MTB) from Clinical Specimens.

Authors:  G Naveen; Basavaraj V Peerapur
Journal:  J Clin Diagn Res       Date:  2012-12-15

10.  Incubation time of Mycobacterium tuberculosis complex sputum cultures in BACTEC MGIT 960: 4weeks of negative culture is enough for physicians to consider alternative diagnoses.

Authors:  Sam Ogwang; Paul Mubiri; Charles M Bark; Moses L Joloba; W Henry Boom; John L Johnson
Journal:  Diagn Microbiol Infect Dis       Date:  2015-07-09       Impact factor: 2.803

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.