Literature DB >> 7489208

Avidin and 111In-labelled biotin scan: a new radioisotopic method for localising vascular graft infection.

R Chiesa1, G Melissano, R Castellano, C Fernandez Zamora, D Astore, A Samuel, G Paganelli, F Fazio, A Grossi.   

Abstract

OBJECTIVES: To evaluate a new imaging technique, for diagnosis of prosthetic vascular graft infection. Avidin is a protein which accumulates nonspecifically at sites of inflammation or infection. Due to its extremely low dissociation constant with biotin sites of infection can be imaged, using avidin as a pre-target, followed by injection of 111In-labelled biotin. This technique is much simpler than the common scintigraphic methods which employ labelling of blood components and its target-to-background ratio is greater than the methods employing radiolabelled proteins.
DESIGN: Prospective clinical study.
SETTING: A single department of vascular surgery and one of nuclear medicine of a Northern Italian hospital. MATERIALS: Between May 1993 and May 1994, 31 grafts in 26 patients were studied; the series included 23 men and three women with a mean age of 65.5 years (range 54-76 years). The prosthetic graft (Dacron -16, ePTFE -15) were: aortoaortic 5, aortobifemoral 15, aortoiliac 1, and femoropopliteal 10. Sixteen patients were suspected of having a vascular graft infection (Group A), the other 10 patients served as controls (Group B). 20 mg of Avidin were injected iv, followed 24 h later by i.v. injection of 500 micrograms of Biotin labelled with 74 MBq of 111In. CHIEF OUTCOME MEASURES: Whole-body imaging was performed at 10 min and 2 h post-injection, along with SPECT imaging when indicated. Scan results were correlated with the traditional imaging modalities and the clinical outcome of the patients. MAIN
RESULTS: In Group A: two patients (three grafts) were excluded from the study, there were six true-positives, one false-positive and 11 true-negatives. Results in Group B: 10 true-negatives. The overall sensitivity was 100%, the specificity 95%, the accuracy 96%, the positive predictive value 86% and the negative predictive value 100%.
CONCLUSIONS: These data suggest that Avidin/111In-labelled Biotin scintigraphy is a useful non invasive diagnostic method for early diagnosis of suspected prosthetic vascular graft infection.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7489208     DOI: 10.1016/s1078-5884(05)80162-5

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  2 in total

1.  Diagnostics of "non-acute" vascular prosthesis infection using 18F-FDG PET/CT: our experience with 96 prostheses.

Authors:  M Spacek; O Belohlavek; J Votrubova; P Sebesta; P Stadler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12-24       Impact factor: 9.236

2.  Clinical feasibility of two-step streptavidin/111In-biotin scintigraphy in patients with suspected vertebral osteomyelitis.

Authors:  Elena Lazzeri; Ernest K J Pauwels; Paola A Erba; Duccio Volterrani; Mario Manca; Lisa Bodei; Donatella Trippi; Antonio Bottoni; Renza Cristofani; Vincenzo Consoli; Christopher J Palestro; Giuliano Mariani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-07-06       Impact factor: 9.236

  2 in total