Literature DB >> 7488950

Application of the premature chromosome condensation assay in simulated partial-body radiation exposures: evaluation of the use of an automated metaphase-finder.

W F Blakely1, P G Prasanna, C J Kolanko, M D Pyle, D M Mosbrook, A S Loats, T L Rippeon, H Loats.   

Abstract

The premature chromosome condensation (PCC) assay has been proposed as a useful and rapid end point for biological dosimetry following accidental high-dose radiation overexposures. A major benefit of the PCC assay is that it does not require cells to divide for evaluation of cytogenetic damage. The PCC assay was performed on isolated human peripheral lymphocytes exposed in vitro to doses from 1 to 9 Gy of 250 kVp x-rays. The dose-response relationships of the frequency distribution and the yield of PCC fragments in cells were determined after one day of repair at 37 degrees C. A Qpcc approach, which involves the analysis of the yield of excess PCC fragments in damaged cells, was used to establish a dose-response calibration curve. This method is identical in concept to the Qdr technique introduced by Sasaki for partial-body exposure dose-estimates using asymmetrical chromosome aberrations (i.e., dicentrics and rings) in metaphase spreads of human lymphocytes. A simulated in vitro test of a partial-body exposure to a 6-Gy dose was performed. The results from this test provided dose estimates of 5.3 +/- 0.6, 4.7 +/- 0.6, 5.0 +/- 0.6 and 4.7 +/- 0.8 Gy for the 20, 30, 50 and 75 percent component of 6-Gy irradiated cells, respectively. An automated metaphase-finding system was evaluated for use with the PCC assay. This system helped to locate PCC spreads among the mitotic inducer Chinese hamster ovary (CHO) metaphase spreads, thereby facilitating rapid scoring of samples.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7488950

Source DB:  PubMed          Journal:  Stem Cells        ISSN: 1066-5099            Impact factor:   6.277


  7 in total

1.  Q(γ-H2AX), an analysis method for partial-body radiation exposure using γ-H2AX in nonhuman primate lymphocytes.

Authors:  Christophe E Redon; Asako J Nakamura; Ksenia Gouliaeva; Arifur Rahman; William F Blakely; William M Bonner
Journal:  Radiat Meas       Date:  2011-09-01       Impact factor: 1.898

2.  Triage dose assessment for partial-body exposure: dicentric analysis.

Authors:  Pataje G S Prasanna; Maria Moroni; Terry C Pellmar
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

3.  Biodosimetry estimation using the ratio of the longest:shortest length in the premature chromosome condensation (PCC) method applying autocapture and automatic image analysis.

Authors:  Jorge E González; Ivonne Romero; Eric Gregoire; Cécile Martin; Ana I Lamadrid; Philippe Voisin; Joan-Francesc Barquinero; Omar García
Journal:  J Radiat Res       Date:  2014-04-30       Impact factor: 2.724

4.  Optimizing the Microscopy Time Schedule for Chromosomal Dosimetry of High-dose and Partial-body Irradiations.

Authors:  Volodymyr A Vinnikov
Journal:  Genome Integr       Date:  2017-01-23

5.  Identification and Preliminary Validation of Radiation Response Protein(s) in Human Blood for a High-throughput Molecular Biodosimetry Technology for the Future.

Authors:  Saibadaiahun Nongrum; S Thangminlal Vaiphei; Joshua Keppen; Mandahakani Ksoo; Ettrika Kashyap; Rajesh N Sharan
Journal:  Genome Integr       Date:  2017-01-23

6.  Construction of Calibration Curve for Premature Chromosome Condensation Assay for Dose Assessment.

Authors:  Elizaveta G Neronova
Journal:  Genome Integr       Date:  2016-12-30

Review 7.  Utilization of cytogenetic biomarkers as a tool for assessment of radiation injury and evaluation of radiomodulatory effects of various medicinal plants - a review.

Authors:  Ravindra M Samarth; Meenakshi Samarth; Yoshihisa Matsumoto
Journal:  Drug Des Devel Ther       Date:  2015-09-25       Impact factor: 4.162

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.