Literature DB >> 7484965

Multiflex versus superelastic: a randomized clinical trial of the tooth alignment ability of initial arch wires.

A E West1, M L Jones, R G Newcombe.   

Abstract

Two arch wires commonly used for initial tooth alignment were compared with regard to their clinical effectiveness. The two arch wires tested were 0.0155-inch diameter multiple-stranded stainless steel wire (Dentaflex, Dentaurium, Optident, Yorkshire, England) and 0.014-inch diameter nickel-titanium alloy wire (NiTi, ORMCO Co., Monrovia, Calif.). Consecutive patients attending an orthodontic clinic for routine placement of a fixed appliance were randomly assigned one of these two initial arch wires. Good quality alginate impressions of the appropriate dental arch were taken before arch wire placement and also at the subsequent appointment, which was, on average, 6 weeks later. Seventy-four arches were used in this study. The degree of tooth alignment achieved for each wire type was compared with a Reflex Microscope (Reflex Measurement Ltd., Butleigh, England) to make detailed measurements on the resultant casts. The degree of initial alignment achieved with the two wires was similar over this 6-week period. However, some differences were found for the lower labial segment where the interbracket span is usually reduced and where the superelastic nickel-titanium wire was found to give improved alignment. No threshold of crowding was found where one arch wire performed better than the other.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7484965     DOI: 10.1016/s0889-5406(95)70046-3

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  13 in total

Review 1.  Which Orthodontic Wire and Working Sequence Should be Preferred for Alignment Phase? A Review.

Authors:  Sedef Sera Hepdarcan; R Burcu Nur Yılmaz; Didem Nalbantgil
Journal:  Turk J Orthod       Date:  2016-06-01

2.  Effect of archwire qualities and bracket designs on the force systems during leveling of malaligned teeth.

Authors:  W Perrey; A Konermann; L Keilig; S Reimann; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

Review 3.  Orthodontic treatment for crowded teeth in children.

Authors:  Sarah Turner; Jayne E Harrison; Fyeza Nj Sharif; Darren Owens; Declan T Millett
Journal:  Cochrane Database Syst Rev       Date:  2021-12-31

4.  Pain and discomfort experienced after placement of a conventional or a superelastic NiTi aligning archwire. A randomized clinical trial.

Authors:  L M Fernandes; B Ogaard; L Skoglund
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

5.  Alignment efficiency of superelastic coaxial nickel-titanium vs superelastic single-stranded nickel-titanium in relieving mandibular anterior crowding: a randomized controlled prospective study.

Authors:  Biju Sebastian
Journal:  Angle Orthod       Date:  2011-10-19       Impact factor: 2.079

6.  A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial.

Authors:  Reem Sh Abdelrahman; Kazem S Al-Nimri; Emad F Al Maaitah
Journal:  Angle Orthod       Date:  2014-08-04       Impact factor: 2.079

7.  Alleviation of Lower Anterior Crowding with Super- Elastic and Heat-Activated NiTi Wires: A Prospective Clinical Trial.

Authors:  Pasupureddi Keerthana; Prasad Chitra
Journal:  Turk J Orthod       Date:  2021-06

Review 8.  Initial arch wires used in orthodontic treatment with fixed appliances.

Authors:  Yan Wang; Chang Liu; Fan Jian; Grant T McIntyre; Declan T Millett; Joy Hickman; Wenli Lai
Journal:  Cochrane Database Syst Rev       Date:  2018-07-31

9.  Forces in initial archwires during leveling and aligning: An in-vitro study.

Authors:  Rajesh Kumar Reddy; Pavan K Katari; Tarun T Bypureddy; Venkata Naga Sri Harsha Anumolu; Yenugupalli Kartheek; Nemala R V Sairam
Journal:  J Int Soc Prev Community Dent       Date:  2016-10-24

10.  A comparative in-vivo evaluation of the alignment efficiency of 5 ligation methods: A prospective randomized clinical trial.

Authors:  Vijaya Bhaskara Reddy; Talapaneni Ashok Kumar; Mandava Prasad; Sivakumar Nuvvula; Rajedra Goud Patil; Praveen Kumar Reddy
Journal:  Eur J Dent       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.