A QA phantom for dynamic stereotactic radiosurgery: quantitative measurements.

R Ramani1, M G Ketko, P F O'Brien, M L Schwartz.   

Abstract

A spherical acrylic phantom was designed for quality assurance measurements of dynamic radiosurgery. The phantom consists of two mating hemispheres mounted on a base plate. The interhemispheric plane may be oriented at any angle to the base, the angle being identified by visible marks on the base plate of the phantom. The phantom has a set of replaceable, radiologically identifiable markers, suitable for Computed Tomography (CT), Magnetic Resonance (MR), and Digital Subtraction Angiography (DSA) imaging. The frame coordinates of each marker are calculated from its known positions with respect to the center of the sphere. The measured errors of these positions using CT and MR images, were within the voxel size of the displayed image, while for DSA images the error was greater than 2.5 mm at the periphery of the image. The calculated depths from the planning software, for various beam intersection points to the isocenter, agreed within 0.6 mm with the known depths. A variation of 3.6 +/- 2.6 mm in the calculated depths was observed between using MR and CT image data. This difference results in a 1% variation in Tissue Maximum ratio (TMR) calculations. Comparisons of measured and known volumes resulted in differences of 8%-10%.

Mesh:

Substances:

Year:  1995        PMID: 7476723     DOI: 10.1118/1.597518

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

Review 1.  Stereotactic radiosurgery: comparing different technologies.

Authors:  M Schwartz
Journal:  CMAJ       Date:  1998-03-10       Impact factor: 8.262

Review 2.  Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques.

Authors:  Pejman Rowshanfarzad; Mahsheed Sabet; Daryl J O'Connor; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

3.  Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

Authors:  David Goodenough; Josh Levy; Smari Kristinsson; Jesper Fredriksson; Hildur Olafsdottir; Austin Healy
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

4.  Dosimetric verification of micro-MLC based intensity modulated radiation therapy.

Authors:  Parminder Basran; Collins Yeboah
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.