Literature DB >> 7476611

Allergy to laboratory animals among animal handlers.

D H Bryant1, L M Boscato, P N Mboloi, M C Stuart.   

Abstract

OBJECTIVE: To determine the prevalence among laboratory animal handlers of allergy to laboratory animals and of asthma and the factors associated with their development.
DESIGN: A cross-sectional survey.
SETTING: Teaching and research institutions in Sydney, between January 1989 and December 1992. PARTICIPANTS: Laboratory animal handlers (teaching and research staff, animal house workers and animal husbandry students and teachers). MAIN OUTCOME MEASURES: Duration of exposure to laboratory animals, allergic symptoms on contact, skin reactivity to laboratory and domestic animal allergens and evidence of current asthma.
RESULTS: 228 subjects were surveyed. Allergy symptoms occurred in 73 (56%) of the subjects exposed to laboratory animals for three months or more. This group also had significantly higher prevalences of skin reactivity to laboratory animal allergens (62%) and bronchial hyperresponsiveness (21%) than those with shorter exposure (14% and 8%, respectively). Atopic subjects exposed to laboratory animals (particularly those sensitised to domestic animals) and animal attendants (with a high intensity of exposure to laboratory animals) had significantly higher frequencies of skin reactivity to laboratory animals and asthma than other subjects (77% and 30%, respectively, among exposed atopic subjects and 84% and 33%, respectively, among animal attendants).
CONCLUSIONS: Allergy to laboratory animals is an occupational hazard among laboratory animal handlers, especially for those who are atopic and sensitised to domestic animals, and may lead to the development of asthma. Screening for atopy and skin reactivity to laboratory animals before and during employment would enable those at risk to take precautions.

Entities:  

Mesh:

Year:  1995        PMID: 7476611     DOI: 10.5694/j.1326-5377.1995.tb124657.x

Source DB:  PubMed          Journal:  Med J Aust        ISSN: 0025-729X            Impact factor:   7.738


  4 in total

1.  Concentration and emission of airborne contaminants in a laboratory animal facility housing rabbits.

Authors:  Tara G Ooms; James E Artwohl; Lorraine M Conroy; Todd M Schoonover; Jeffrey D Fortman
Journal:  J Am Assoc Lab Anim Sci       Date:  2008-03       Impact factor: 1.232

Review 2.  Rodent allergens.

Authors:  Wanda Phipatanakul
Journal:  Curr Allergy Asthma Rep       Date:  2002-09       Impact factor: 4.919

3.  Prevalence of occupational allergy in medical researchers exposed to laboratory animals.

Authors:  Basilua Andre Muzembo; Masamitsu Eitoku; Yuta Inaoka; Makiko Oogiku; Mitomo Kawakubo; Ryuta Tai; Momoko Takechi; Ken-ichi Hirabayashi; Naofumi Yoshida; Nlandu Roger Ngatu; Ryoji Hirota; Bernardus Sandjaya; Narufumi Suganuma
Journal:  Ind Health       Date:  2014-02-28       Impact factor: 2.179

4.  B cells modulate mouse allergen-specific T cells in nonallergic laboratory animal-care workers.

Authors:  Esther Dawen Yu; Luise Westernberg; Alba Grifoni; April Frazier; Aaron Sutherland; Eric Wang; Bjoern Peters; Ricardo da Silva Antunes; Alessandro Sette
Journal:  JCI Insight       Date:  2021-02-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.