Literature DB >> 7475229

Multi-electrode array for measuring evoked potentials from surface of ferret primary auditory cortex.

A L Owens1, T J Denison, H Versnel, M Rebbert, M Peckerar, S A Shamma.   

Abstract

Using silicon-integrated circuit technology, we have fabricated a flexible multi-electrode array and used it for measuring evoked potentials at the surface of the ferret primary auditory cortex (AI). Traditionally, maps of cortical activity are recorded from numerous sequential penetrations with a single electrode. A common problem with this approach is that the state of the cortex (defined in part by level of anesthesia and number of active cells) changes during the time required to generate these maps. The multi-electrode array reduces this problem by allowing the recording of 24 locations simultaneously. The specific array described in this report is designed to record cortical activity over a 1 mm2 area. It is comprised of 24 gold electrodes (40 x 40 microns2) each spaced 210 microns apart. These electrodes are connected to contact pads via gold leads (5 cm in length). The electrodes, leads, and contact pads are sandwiched between two layers of polyimide. The polyimide passivates the device and makes the device flexible enough to conform to the shape of the cortex. The fabrication procedures described here allow various other layouts and areas to be readily implemented. Measurements of the electrical properties of the electrodes, together with details of the multichannel amplification, acquisition, and display of the data are also discussed. Finally, results of AI mapping experiments with these arrays are illustrated.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7475229     DOI: 10.1016/0165-0270(94)00178-j

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  3 in total

1.  Modular organization of intrinsic connections associated with spectral tuning in cat auditory cortex.

Authors:  H L Read; J A Winer; C E Schreiner
Journal:  Proc Natl Acad Sci U S A       Date:  2001-07-03       Impact factor: 11.205

2.  A high-density, high-channel count, multiplexed μECoG array for auditory-cortex recordings.

Authors:  Monty A Escabí; Heather L Read; Jonathan Viventi; Dae-Hyeong Kim; Nathan C Higgins; Douglas A Storace; Andrew S K Liu; Adam M Gifford; John F Burke; Matthew Campisi; Yun-Soung Kim; Andrew E Avrin; Van der Spiegel Jan; Yonggang Huang; Ming Li; Jian Wu; John A Rogers; Brian Litt; Yale E Cohen
Journal:  J Neurophysiol       Date:  2014-06-11       Impact factor: 2.714

3.  Towards in vivo neural decoding.

Authors:  Daniel Valencia; Amir Alimohammad
Journal:  Biomed Eng Lett       Date:  2022-02-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.