Literature DB >> 7473120

Effect of age and astigmatism on the AMO Array multifocal intraocular lens.

P C Jacobi1, W Konen.   

Abstract

Multifocal intraocular lenses (MIOLs) have been designed to provide better uncorrected near visual acuity than monofocal IOLs. However, the increase in depth of focus is combined with a significant decrease in contrast sensitivity and glare. We implanted a new zonal-progressive MIOL (AMO Array) in 31 eyes of 25 patients whose mean age was 60.8 +/- 13.5 years. At 12.1 +/- 2.4 months postoperatively, the uncorrected visual acuity averaged 0.56 +/- 0.09 (20/32) for distance and 0.54 +/- 0.12 (20/40) for near focus. Seventy-five percent of patients achieved a best corrected distance visual acuity of > or = 0.9 (20/22). With distance correction only, mean near visual acuity was 0.72 +/- 0.17 (20/25). Best corrected near acuity reached 0.89 +/- 0.11 (20/22), requiring an additional near add of +1.0 to +2.0 diopters (D). We observed an age-dependent difference in the depth of focus. In younger patients (46 +/- 6 years), the pseudoaccommodation range was 6.25 D; acuity attained was > or = 0.4 (20/50). In older patients (71 +/- 7 years), visual acuity at the near focus was substantially reduced (two lines). Regan contrast sensitivity was lower for MIOL patients at all contrast levels, but the difference was statistically significant only at very low contrast (11%). Contrast sensitivity and glare were dependent on the patient's age but did not change with the amount of postoperative astigmatism. Younger patients were very satisfied with the results of MIOL implantation, and the small loss of contrast sensitivity was counterbalanced by the advantage of improved depth of focus and uncorrected near visual acuity.

Entities:  

Mesh:

Year:  1995        PMID: 7473120     DOI: 10.1016/s0886-3350(13)80217-9

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

1.  Visual simulation of retinal images through a decentered monofocal and a refractive multifocal intraocular lens.

Authors:  Kazuno Negishi; Kazuhiko Ohnuma; Takashi Ikeda; Toru Noda
Journal:  Jpn J Ophthalmol       Date:  2005 Jul-Aug       Impact factor: 2.447

2.  Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation.

Authors:  S Schmitz; H B Dick; F Krummenauer; O Schwenn; R Krist
Journal:  Br J Ophthalmol       Date:  2000-10       Impact factor: 4.638

3.  Dissatisfaction after multifocal intraocular lens implantation.

Authors:  Maria A Woodward; J Bradley Randleman; R Doyle Stulting
Journal:  J Cataract Refract Surg       Date:  2009-06       Impact factor: 3.351

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.