Literature DB >> 7472725

Three-dimensional distortion of gold alloy castings and welded titanium frameworks. Measurements of the precision of fit between completed implant prostheses and the master casts in routine edentulous situations.

T Jemt1.   

Abstract

Thirty routine patients, provided with fixed prostheses supported by osseointegrated Brånemark implants in edentulous lower jaws, were arranged into three different groups with regard to design of the metal framework. Ten patients received cast gold alloy frames and the other two groups were provided with two different designs of welded titanium frames. The fit of the completed prostheses was measured in three dimensions (3-D) in relation to the master cast, by means of a photogrammetric technique, prior to insertion. Mean 3-D distortion of the centre point of the gold cylinder was 42 (s.d. 8) microns for the cast framework. The corresponding mean distortion for the two designs of titanium frameworks was 43 (s.d. 16) and 36 (s.d. 10) microns, respectively. Least distortion was observed in vertical direction for all three designs. None of the different designs of metal frames showed a significantly better fit (P > 0.05), but the cast and oldest titanium framework design presented a much wider range of distortion. This indicated a higher risk of sectioning and resoldering during the fabrication of the prostheses as compared to the more consistently fabricated prostheses, with a new titanium framework design.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7472725     DOI: 10.1111/j.1365-2842.1995.tb01049.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  7 in total

1.  CAD/CAM technologies in the surgical and prosthetic treatment of the edentulous patient with biomymetic individualized approach.

Authors:  A Pozzi; M Gargari; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

2.  Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

Authors:  Raquel Castillo-de-Oyagüe; Andrés Sánchez-Turrión; José-Francisco López-Lozano; Alberto Albaladejo; Daniel Torres-Lagares; Javier Montero; Maria-Jesús Suárez-García
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-07-01

3.  Precision of fit of titanium and cast implant frameworks using a new matching formula.

Authors:  Marianella Sierraalta; Jose L Vivas; Michael E Razzoog; Rui-Feng Wang
Journal:  Int J Dent       Date:  2012-04-08

4.  Three-dimensional accuracy of different correction methods for cast implant bars.

Authors:  Ji-Yung Kwon; Chang-Whe Kim; Young-Jun Lim; Ho-Beom Kwon; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

5.  Fully Digital versus Conventional Workflows for Fabricating Posterior Three-Unit Implant-Supported Reconstructions: A Prospective Crossover Clinical Trial.

Authors:  Ali Mahmoud Hashemi; Hamid Mahmoud Hashemi; Hakimeh Siadat; Ahmadreza Shamshiri; Kelvin Ian Afrashtehfar; Marzieh Alikhasi
Journal:  Int J Environ Res Public Health       Date:  2022-09-12       Impact factor: 4.614

6.  The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding.

Authors:  Daniela Castilio; Ana Paula Ribeiro do Vale Pedreira; Paulo Henrique Orlato Rossetti; Leylha Maria Nunes Rossetti; Wellington Cardoso Bonachela
Journal:  J Appl Oral Sci       Date:  2006-04       Impact factor: 2.698

7.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01
  7 in total