Literature DB >> 7470402

Lung function of office workers exposed to humidifier fever antigen.

I Ashton, A T Axford, C Bevan, J E Cotes.   

Abstract

Office workers who became sensitised to antigens derived from humidifier sludge developed episodes of fever, malaise, and other symptoms, including polyuria and mild chest tightness. The episodes usually occurred on a Monday evening and were to some extent dose-related. Lung function was assessed over a day shift on two occasions, including one after which almost all the susceptible subjects developed symptoms. The symptoms were preceded by a 6% reduction in forced expiratory volume and vital capacity, a corresponding increase in residual volume, and a reduction in flow rate after 75% vital capacity had been expired. There were no changes in peak expiratory flow, forced expiratory flow at 50% of vital capacity, or transfer factor. In some subjects the transfer factor was apparently reduced 36 hours later, but for this there may have been another explanation. The physiological features were considered to reflect narrowing of small airways in the lung. The changes, however, were minimal and not the main cause of the symptoms. A feature of the episode was the severity of the constitutional symptoms despite the low airborne dust levels.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7470402      PMCID: PMC1008795          DOI: 10.1136/oem.38.1.34

Source DB:  PubMed          Journal:  Br J Ind Med        ISSN: 0007-1072


  5 in total

1.  Interstital lung disease due to contamination of forced air systems.

Authors:  J N Fink; E F Banaszak; J J Barboriak; G T Hensley; V P Kurup; G T Scanlon; D P Schlueter; A J Sosman; W H Thiede; G F Unger
Journal:  Ann Intern Med       Date:  1976-04       Impact factor: 25.391

2.  Humidifier fever in an operating theatre.

Authors:  I A Campbell; A E Cockcroft; J H Edwards; M Jones
Journal:  Br Med J       Date:  1979-10-27

3.  Digital incremental techniques applied to spirometry.

Authors:  M McDermott; T J McDermott
Journal:  Proc R Soc Med       Date:  1977-03

4.  Extrinsic allergic alveolitis and contaminated cooling-water in a factory machine.

Authors:  J A Friend; J Gaddie; K N Palmer; C A Pickering; J Pepys
Journal:  Lancet       Date:  1977-02-05       Impact factor: 79.321

5.  Microbial and immunological investigations and remedial action after an outbreak of humidifier fever.

Authors:  J H Edwards
Journal:  Br J Ind Med       Date:  1980-02
  5 in total
  3 in total

Review 1.  Building-related illness. A review of available scientific data.

Authors:  E J Bardana; A Montanaro; M T O'Hollaren
Journal:  Clin Rev Allergy       Date:  1988

2.  Lung function of workers exposed to antigens from a contaminated air-conditioning system.

Authors:  T M Pal; H F Kaufmann; J G de Monchy; K de Vries
Journal:  Int Arch Occup Environ Health       Date:  1985       Impact factor: 3.015

3.  Indirect health effects of relative humidity in indoor environments.

Authors:  A V Arundel; E M Sterling; J H Biggin; T D Sterling
Journal:  Environ Health Perspect       Date:  1986-03       Impact factor: 9.031

  3 in total