Literature DB >> 7465843

Scintigraphic detection of pulmonary embolism in patients with obstructive pulmonary disease.

P O Alderson, D R Biello, K G Sachariah, B A Siegel.   

Abstract

The 133Xe ventilation (V) studies, 99mTc perfusion (P) lung images, and pulmonary angiograms of 83 patients with obstructive pulmonary disease (OPD) and suspected pulmonary emboli (PE) were reviewed. Each patient had ventilation abnormalities suggesting OPD and at least one region showing matched V-P abnormalities. All angiograms were obtained within 72 hours of the V-P study and were reviewed independently. The overall sensitivity of V-P imaging for PE in this population was 0.83 and its specificity was 0.92. False-negative interpretations occurred in three of the 16 patients who showed ventilation abnormalities in more than 50% of their lung fields. In the 67 patients with ventilation abnormalities in less than or equal to 50% of their lung fields the sensitivity (0.95) and specificity (0.94) for detecting PE were high, V-P imaging is a reliable method for detecting PE in patients with regions of V-P match, if the ventilation abnormalities are limited in extent.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7465843     DOI: 10.1148/radiology.138.3.7465843

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Fibrin degradation product D-dimer in the diagnosis of pulmonary embolism.

Authors:  J Lichey; I Reschofski; T Dissmann; M Priesnitz; M Hoffmann; H Lode
Journal:  Klin Wochenschr       Date:  1991-08-16

Review 2.  The value of lung scintigraphy in the diagnosis of pulmonary embolism.

Authors:  E J van Beek; M M Tiel-van Buul; H R Büller; E A van Royen; J W ten Cate
Journal:  Eur J Nucl Med       Date:  1993-02

3.  Diagnostic approach to pulmonary embolism: our strategy.

Authors:  A Vincent; S Poli; C Perret
Journal:  Intensive Care Med       Date:  1984       Impact factor: 17.440

4.  Pulmonary digital subtraction angiography.

Authors:  J Kollath; H Riemann
Journal:  Cardiovasc Intervent Radiol       Date:  1983       Impact factor: 2.740

5.  Plasma cross linked fibrin degradation products in pulmonary embolism.

Authors:  B J Rowbotham; J Egerton-Vernon; A N Whitaker; M J Elms; I H Bunce
Journal:  Thorax       Date:  1990-09       Impact factor: 9.139

6.  99mTc-DTPA and 99mTc-rhenium sulfur aerosol compared as adjuncts to perfusion scintigraphy in patients with suspected pulmonary embolism.

Authors:  P Peltier; J F Chatal
Journal:  Eur J Nucl Med       Date:  1986

7.  A comparison of SPECT and planar ventilation perfusion lung scanning.

Authors:  S Eustace; N Phelan; D J Dowsett; J T Ennis
Journal:  Ir J Med Sci       Date:  1993-03       Impact factor: 1.568

8.  Scintigraphic evaluation of pulmonary embolism.

Authors:  P O Alderson
Journal:  Eur J Nucl Med       Date:  1987
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.