Literature DB >> 7457715

Indwelling ileostomy valve device.

O H Beahrs, M A Bess, R W Beart, J H Pemberton.   

Abstract

Complications after construction of a continent ileostomy may require reoperation to restore continence. Although most patients accept another operation, a few refuse further operative intervention. In such patients we have employed an indwelling ileostomy valve device. A Silastic tube with a circumferential balloon to provide a leakproof seal functionally replaces the nipple valve that has failed. In 14 patients, the valve device has maintained continuous and voluntary control over evacuation without untoward local or systemic effects. If further investigation continues to support this approach to maintaining continence, use of an indwelling ileostomy valve device might be preferable to continued creation of the nipple valve.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7457715     DOI: 10.1016/0002-9610(81)90022-2

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  2 in total

1.  Kock pouch dysfunction during pregnancy. Management of a case.

Authors:  R D Curtis; W B Sweeney; J W Denobile; E Hurwitz
Journal:  Surg Endosc       Date:  1996-07       Impact factor: 4.584

2.  A continent ileostomy device.

Authors:  J H Pemberton; J A van Heerden; R W Beart; K A Kelly; S F Phillips; B M Taylor
Journal:  Ann Surg       Date:  1983-05       Impact factor: 12.969

  2 in total