Literature DB >> 7456822

[Auto-suture stapler EEA in surgery of the colon and rectum [author's transl)].

A Thiede, H Troidl, H Poser, L Jostarndt, H Hamelmann.   

Abstract

The increasing use of auto-suture staplers for gastrointestinal anastomoses makes it necessary to test the value of this new method of suturing. In a "pilot study" the practicability, the tightness and permeability of the anastomosis and complications were tested and analysed in a total of 30 colon and rectal anastomoses using the EEA-suture gun. The results of 14 colon resections and 16 low anterior resections justify the further use of the EEA auto-suture apparatus and raise the question of a prospective controlled random study in which manual and mechanical machine sutured anastomoses are compared.

Entities:  

Mesh:

Year:  1980        PMID: 7456822

Source DB:  PubMed          Journal:  Zentralbl Chir        ISSN: 0044-409X            Impact factor:   0.942


  2 in total

1.  [Comparative results of EEA and SPTU staplers used for colo-rectal anastomoses in 260 patients (author's transl)].

Authors:  S Athanasiadis; B A Barry; J Girona
Journal:  Langenbecks Arch Chir       Date:  1981

2.  [Causes of anastomotic dehiscence].

Authors:  S Langer; D Kupczyk
Journal:  Langenbecks Arch Chir       Date:  1982
  2 in total