Literature DB >> 7436622

Obstruction of the true lumen during retrograde perfusion of type I aortic dissections: a simplified solution.

G V Parr, N J Manley, D R Williams, R M Montesano.   

Abstract

Retrograde perfusion of the false lumen in cases of type I dissection of the thoracic aorta may not permit reperfusion of the coronary arteries when the aortic cross-clamp is removed. We have employed a Y connector between the coronary perfusion outlet of the oxygenator and cardioplegia delivery system. This allows reperfusion of the coronary arteries through the ascending aortic graft. As cardiopulmonary bypass is discontinued, the true aortic lumen is reexpanded and the false lumen collapsed by forward flow of blood from the heart. The successful use of this system is described.

Entities:  

Mesh:

Year:  1980        PMID: 7436622     DOI: 10.1016/s0003-4975(10)61305-7

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  1 in total

1.  Stanford type A aortic dissection. A new surgical approach.

Authors:  A Lijoi; F Scarano; V Dottori; E Parodi; G Casali; F Bartolozzi
Journal:  Tex Heart Inst J       Date:  1998
  1 in total