Literature DB >> 7436578

Metal sensitivity causing loosened joint prostheses.

K Christiansen, K Holmes, P J Zilko.   

Abstract

Metal sensitivity, as measured by an in-vitro assay on peripheral blood lymphocytes, was evaluated in patients with failed joint prostheses. Lymphocyte transformation to chromium, cobalt, and nickel was measured in 24 patients having revision surgery for a painful or loose prosthesis and compared with that in 11 patients who had a successful hip prothesis in situ for at least 2 years previously. A positive response (lymphocyte stimulation index greater than 3) to at least one of the metals was found in 71% of the revision group compared to 9% of controls (P < 0.01). The positive correlation between prosthesis failure and in-vitro metal sensitivity suggests that cell-mediated immunity to metals to metals may play a role in prosthesis failure. Furthermore, this simple in-vitro test may provide the basis of a useful diagnostic test for an often difficult clinical problem.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7436578      PMCID: PMC1000589          DOI: 10.1136/ard.39.5.476

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  13 in total

1.  Systemic and local complications following low-friction arthroplasty of the hip joint. A study of 800 consecutive operations.

Authors:  N S Eftekhar; H A Kiernan; F E Stinchfield
Journal:  Arch Surg       Date:  1976-02

2.  Concentration of wear products in hair, blood, and urine after total hip replacement.

Authors:  R F Coleman; J Herrington; J T Scales
Journal:  Br Med J       Date:  1973-03-03

3.  In vitro studies of contact hypersensitivity: lymphocyte transformation in nickel sensitivity.

Authors:  L E Millikan; F Conway; J E Foote
Journal:  J Invest Dermatol       Date:  1973-02       Impact factor: 8.551

4.  Laboratory tests on total joint replacement prostheses.

Authors:  S A Swanson; M A Freeman; J C Heath
Journal:  J Bone Joint Surg Br       Date:  1973-11

5.  The uptake of labelled thymidine by leucocytes of nickel sensitive patients.

Authors:  T M Macleod; F Hutchinson; E J Raffle
Journal:  Br J Dermatol       Date:  1970-05       Impact factor: 9.302

6.  Sensitivity to metal as a possible cause of sterile loosening after cobalt-chromium total hip-replacement arthroplasty.

Authors:  G C Brown; M D Lockshin; E A Salvati; P G Bullough
Journal:  J Bone Joint Surg Am       Date:  1977-03       Impact factor: 5.284

7.  Rejection of metal to metal prosthesis and skin sensitivity to cobalt.

Authors:  D Munro-Ashman; A J Miller
Journal:  Contact Dermatitis       Date:  1976-04       Impact factor: 6.600

8.  Incidence of metal sensitivity in patients with total joint replacements.

Authors:  M W Elves; J N Wilson; J T Scales; H B Kemp
Journal:  Br Med J       Date:  1975-11-15

9.  Metal sensitivity in patients with joint replacement arthroplasties.

Authors:  M K Benson; P G Goodwin; J Brostoff
Journal:  Br Med J       Date:  1975-11-15

10.  Complications of total hip arthroplasty treated by reoperation.

Authors:  D R Nolan; R H Fitzgerald; R D Beckenbaugh; M B Coventry
Journal:  J Bone Joint Surg Am       Date:  1975-10       Impact factor: 5.284

View more
  7 in total

1.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

Review 2.  The lexicon for periprosthetic bone loss versus osteolysis after cervical disc arthroplasty: a systematic review.

Authors:  Jenna M Wahbeh; Sang-Hyun Park; Patricia Campbell; Edward Ebramzadeh; Sophia N Sangiorgio
Journal:  Eur Spine J       Date:  2022-01-09       Impact factor: 3.134

3.  Adverse Reaction to Zirconia in a Modern Total Hip Arthroplasty with Ceramic Head.

Authors:  Kwesi G Dawson-Amoah; Bradford S Waddell; Rohan Prakash; Michael M Alexiades
Journal:  Arthroplast Today       Date:  2020-06-19

Review 4.  Is patient selection important for hip resurfacing?

Authors:  Ryan M Nunley; Craig J Della Valle; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

Review 5.  Metal Hypersensitivity Reactions to Orthopedic Implants.

Authors:  Wendy Z W Teo; Peter C Schalock
Journal:  Dermatol Ther (Heidelb)       Date:  2016-12-19

6.  Increased risk of eczema after joint replacement: A population-based retrospective cohort study.

Authors:  Po-Yuan Wu; Chih-Hsin Muo; Chun-Hao Tsai
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

7.  Metal-induced delayed type hypersensitivity responses potentiate particle induced osteolysis in a sex and age dependent manner.

Authors:  Lauryn Samelko; Marco Caicedo; Kyron McAllister; Joshua Jacobs; Nadim James Hallab
Journal:  PLoS One       Date:  2021-05-18       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.