Literature DB >> 7426593

Tear glucose levels in normal people and in diabetic patients.

D K Sen, G S Sarin.   

Abstract

Fifty normal people and 50 diabetic patients were studied by means of an enzymatic method for the glucose content in the blood, tears, and urine before and after the peroral glucose load. In normal subjects the fasting glucose levels in the tears averaged 3.6 mg/100 ml (0.2 mmol/l) and in the diabetic patients it averaged 16.6 mg/100 ml (0.92 mmol/l). As in blood and urine, tear glucose levels are significantly higher in diabetic patients than normal persons both at fasting and after the peroral glucose load test. The fasting tear glucose level did not appear to be a satisfactory index for classifying a person as a diabetic or normal. It was found that after the peroral glucose load test a tear glucose level at 11 mg/100 ml (0.61 mmol/l) resulted in only 4.6% of the diabetics being missed, while 5.8% of the normal persons were misclassified as diabetics.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7426593      PMCID: PMC1043796          DOI: 10.1136/bjo.64.9.693

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  5 in total

1.  Tear glucose in diabetics.

Authors:  J G LEWIS
Journal:  Br J Ophthalmol       Date:  1958-12       Impact factor: 4.638

2.  Use of glucose oxidase, peroxidase, and O-dianisidine in determination of blood and urinary glucose.

Authors:  A S HUGGETT; D A NIXON
Journal:  Lancet       Date:  1957-08-24       Impact factor: 79.321

3.  Immunoglobulins in tears of normal Indian people.

Authors:  D K Sen; G S Sarin; K Mani; K Saha
Journal:  Br J Ophthalmol       Date:  1976-04       Impact factor: 4.638

4.  Concentration of glucose and total chloride in tears.

Authors:  A GIARDINI; J R E ROBERTS
Journal:  Br J Ophthalmol       Date:  1950-12       Impact factor: 4.638

5.  Tear glucose detection of hyperglycemia.

Authors:  A R Gasset; L E Braverman; M C Fleming; R A Arky; B R Alter
Journal:  Am J Ophthalmol       Date:  1968-03       Impact factor: 5.258

  5 in total
  25 in total

1.  A disposable tear glucose biosensor-part 1: design and concept testing.

Authors:  Daniel K Bishop; Jeffrey T La Belle; Stephen R Vossler; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

Review 2.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

3.  A graphene-based affinity nanosensor for detection of low-charge and low-molecular-weight molecules.

Authors:  Yibo Zhu; Yufeng Hao; Enoch A Adogla; Jing Yan; Dachao Li; Kexin Xu; Qian Wang; James Hone; Qiao Lin
Journal:  Nanoscale       Date:  2016-03-21       Impact factor: 7.790

Review 4.  Noninvasive diagnostic devices for diabetes through measuring tear glucose.

Authors:  Jin Zhang; William Hodge; Cindy Hutnick; Xianbin Wang
Journal:  J Diabetes Sci Technol       Date:  2011-01-01

5.  Harnessing a nanostructured fluorescence energy transfer sensor for quick detection of extremely small amounts of glucose.

Authors:  Jin Zhang; Xianbin Wang; Longyan Chen; Jiaxin Li; Kevin Luzak
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

Review 6.  Wireless and battery-free platforms for collection of biosignals.

Authors:  Tucker Stuart; Le Cai; Alex Burton; Philipp Gutruf
Journal:  Biosens Bioelectron       Date:  2021-01-23       Impact factor: 10.618

Review 7.  Stimuli sensitive polymers and self regulated drug delivery systems: a very partial review.

Authors:  Ronald A Siegel
Journal:  J Control Release       Date:  2014-06-28       Impact factor: 9.776

8.  Evaluation of lacrimal fluid as an alternative for monitoring glucose in critically ill patients.

Authors:  Jaclyn M Leblanc; Curtis E Haas; Glorimar Vicente; Luis A Colon
Journal:  Intensive Care Med       Date:  2005-08-16       Impact factor: 17.440

9.  Non enzymatic fluorometric determination of glucose by using quenchable g-C3N4 quantum dots.

Authors:  Xiaorong Gan; Huimin Zhao; Romana Schirhagl; Xie Quan
Journal:  Mikrochim Acta       Date:  2019-11-15       Impact factor: 5.833

10.  Portable system for the detection of micromolar concentrations of glucose.

Authors:  Yordan Kostov; Xudong Ge; Govind Rao; Leah Tolosa
Journal:  Meas Sci Technol       Date:  2014       Impact factor: 2.046

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.