Literature DB >> 7425378

Time-weighted averaging for nitrous oxide: an automated method.

W A McGill, O Rivera, R Howard.   

Abstract

An automated method of obtaining a time-weighted average of nitrous oxide levels in an operating room was compared with a standard method. The automated method consisted of electronic integration of the voltage output of a nitrous oxide analyzer using a multimeter-microprocessor. The standard method utilized a bag and pump to collect a room air sample, which was subsequently analyzed with a nitrous oxide analyzer. There was a high degree of correlation (r = 0.99) between the two methods. It is concluded that the automated method is an accurate alternative and offers institutions a simple, cost-effective method of monitoring and documenting results of pollution control programs in anesthetizing locations.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7425378     DOI: 10.1097/00000542-198011000-00008

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892