Literature DB >> 7420159

Direct retraction method in aneurysm surgery. Technical note.

K Sugita, S Kobayashi, T Takemae, K Matsuo, A Yokoo.   

Abstract

A new technique of direct retraction of an aneurysm or major arteries using tapered brain retractors is introduced. The system requires three separate instruments: 1) a tappered brain retractor, 2) a flexible self-retaining retractor of light weight, and 3) a multipurpose head frame.

Entities:  

Mesh:

Year:  1980        PMID: 7420159     DOI: 10.3171/jns.1980.53.3.0417

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  8 in total

1.  Self-retaining brain retractor pressure during intracranial procedures.

Authors:  J Rosenørn
Journal:  Acta Neurochir (Wien)       Date:  1987       Impact factor: 2.216

2.  The influence of intermittent versus continuous brain retractor pressure on regional cerebral blood flow and neuropathology in the rat.

Authors:  J Rosenørn; N H Diemer
Journal:  Acta Neurochir (Wien)       Date:  1988       Impact factor: 2.216

3.  Technical pitfalls in a porcine brain retraction model. The impact of brain spatula on the retracted brain tissue in a porcine model: a feasibility study and its technical pitfalls.

Authors:  R Thiex; F J Hans; T Krings; B Sellhaus; J M Gilsbach
Journal:  Neuroradiology       Date:  2005-09-01       Impact factor: 2.804

4.  An improved neurosurgical system: new operating table, chair, microscope and other instrumentation.

Authors:  S Kobayashi; K Sugita; K Matsuo
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

5.  Combined retractor and hand-rest system for neurosurgery.

Authors:  J M Gilsbach; T Lutze; W Seeger
Journal:  Neurosurg Rev       Date:  1984       Impact factor: 3.042

6.  The influence of the profile of brain retractors on regional cerebral blood flow in the rat.

Authors:  J Rosenørn; N H Diemer
Journal:  Acta Neurochir (Wien)       Date:  1987       Impact factor: 2.216

7.  Occipital Interhemispheric Approach for Surgical Removal of the Middle Third Falx Meningioma: Two Case Reports.

Authors:  Naoki Otani; Kojiro Wada; Terushige Toyooka; Kentaro Mori
Journal:  Asian J Neurosurg       Date:  2018 Jul-Sep

8.  The interhemispheric fissure-surgical outcome of interhemispheric approaches.

Authors:  A Kaywan Aftahy; Melanie Barz; Arthur Wagner; Friederike Liesche-Starnecker; Chiara Negwer; Bernhard Meyer; Jens Gempt
Journal:  Neurosurg Rev       Date:  2020-08-27       Impact factor: 3.042

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.