Literature DB >> 7410193

Stereo-projection radiography in the study of the structural organisation of cat skull bones.

J C Buckland-Wright.   

Abstract

The relatively low resolution in the radiographs produced by clinical X-ray machines has led to the rejection, by a number of investigators, of this machine as a method of examining the detailed structural organisation of bone. In the recently developed microfocal X-ray unit a fine beam of electrons is focussed onto the side of a water cooled target. Stereo-projection radiographs of specimens can be produced at magnifications of x 1-100 and a theoretical resolution to the diamter of the X-ray source (5-10 micrometer). The application of stereo-projection radiography to the study of cat skulls revealed details of structure not readily visible with conventional X-ray techniques. Using three different methods, the shadow images of trabeculae and vascular canals seen in the radiographs were closely correlated with the structures observed in the coronal sections and dissected regions of the cat skulls. The smallest structures recorded from the radiographs had a diameter of 60 micrometer. The effect of the depth of bone and of overlapping trabeculae and large vascular canals on the number of osseous structures recorded in the radiographs of five cat skulls was assessed. The results showed that 50% of the trabeculae and large vascular canals were no longer visible at a bone depth of 4 and 1x5 mm respectively and when superimposed by twelve and two structures respectively.

Entities:  

Mesh:

Year:  1980        PMID: 7410193      PMCID: PMC1233168     

Source DB:  PubMed          Journal:  J Anat        ISSN: 0021-8782            Impact factor:   2.610


  5 in total

1.  Origin of registration of the architectural pattern, the lamina dura, and the alveolar crest in the dental radiograph.

Authors:  H M GOLDMAN; J S MILLSAP; H S BRENMAN
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1957-07

2.  The micro-focal x-ray unit and its application to bio-medical research.

Authors:  J C Buckland-Wright
Journal:  Experientia       Date:  1976-12-15

3.  Bone destruction not demonstrable by radiography.

Authors:  G M ARDRAN
Journal:  Br J Radiol       Date:  1951-02       Impact factor: 3.039

4.  The micro-focal x-ray unit: a demonstration of its potential.

Authors:  J C Buckland-Wright
Journal:  Med Biol Illus       Date:  1977-11

5.  Bone structure and the patterns of force transmission in the cat skull (felis catus).

Authors:  J C Buckland-Wright
Journal:  J Morphol       Date:  1978-01       Impact factor: 1.804

  5 in total
  1 in total

1.  Quantitative microfocal radiography accurately detects joint changes in rheumatoid arthritis.

Authors:  J C Buckland-Wright; I Carmichael; S R Walker
Journal:  Ann Rheum Dis       Date:  1986-05       Impact factor: 19.103

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.