Literature DB >> 7409831

Semiautomated autoradiographic measurement of DNA repair in normal and xeroderma pigmentosum cultured human fibroblasts.

K H Kraemer, J K Buchanan, S F Stinson.   

Abstract

Assessment of DNA repair in cultured human fibroblasts by autoradiography may be facilitated by using semiautomated grain counting instruments. The instrument-determined number of autoradiographic grains per nucleus in cultured human skin fibroblasts was found to be linear in comparison to visual counts up to only 30 grains per nucleus. However, with two different instruments a greater range of linearity (to 100 to 120 grains per nucleus) was attained by measuring the grain surface area per nucleus. Semiautomated analysis of the grain surface area per nucleus yielded measurements of relative rates of unscheduled DNA synthesis after ultraviolet irradiation in xeroderma pigmentosum and normal human fibroblasts, which were reproducible and rapid.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7409831     DOI: 10.1007/BF02618386

Source DB:  PubMed          Journal:  In Vitro        ISSN: 0073-5655


  6 in total

1.  Genetic heterogeneity in xeroderma pigmentosum: complementation groups and their relationship to DNA repair rates.

Authors:  K H Kraemer; H G Coon; R A Petinga; S F Barrett; A E Rahe; J H Robbins
Journal:  Proc Natl Acad Sci U S A       Date:  1975-01       Impact factor: 11.205

2.  Automated autoradiographic grain counting in human determined context.

Authors:  L E Lipkin; P Lemkin; G Carman
Journal:  J Histochem Cytochem       Date:  1974-07       Impact factor: 2.479

3.  Xeroderma pigmentosum. An inherited diseases with sun sensitivity, multiple cutaneous neoplasms, and abnormal DNA repair.

Authors:  J H Robbins; K H Kraemer; M A Lutzner; B W Festoff; H G Coon
Journal:  Ann Intern Med       Date:  1974-02       Impact factor: 25.391

4.  Automated image analysis in autoradiography.

Authors:  W Prensky
Journal:  Exp Cell Res       Date:  1971-10       Impact factor: 3.905

5.  Rapid grain and cell counting for cell kinetic studies.

Authors:  P A Bunn; S S Ford; S E Shackney
Journal:  J Natl Cancer Inst       Date:  1977-07       Impact factor: 13.506

6.  An automated system for counting silver grains in autoradiographs.

Authors:  D F Wann; J L Price; W M Cowan; M A Agulnek
Journal:  Brain Res       Date:  1974-11-29       Impact factor: 3.252

  6 in total
  1 in total

1.  Quantitation of autoradiographic grains in different zones of articular cartilage with image analyzer.

Authors:  J J Parkkinen; K Paukkonen; E Pesonen; M J Lammi; S Markkanen; H J Helminen; M Tammi
Journal:  Histochemistry       Date:  1990
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.