Literature DB >> 740172

Comparison of cerebrospinal fluid dynamics studied by computed tomography (CT) and radioisotope (RI) cisternography.

N Tamaki, Y Kanazawa, M Asada, T Kusunoki, S Matsumoto.   

Abstract

CT and RI cisternography were done on 55 cases with normal and abnormal CSF circulation. Of 19 cases in which both studies were done, 14 case disclosed a good correspondence. The remaining five cases showed no correspondence because of technical failure. Analyzing the results, CT cisternography demonstrates pathology of the CSF dynamics in a more precise and quantitative manner than RI cisternography does. Metrizamide CT cisternography will soon be the most reliable method of investigation for the evaluation of the CSF kinetics.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 740172     DOI: 10.1007/bf00395248

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  7 in total

1.  RISA-VENTRICULOGRAPHY AND RISA-CISTERNOGRAPHY.

Authors:  G DICHIRO; P M REAMES; W B MATTHEWS
Journal:  Neurology       Date:  1964-03       Impact factor: 9.910

2.  Computer assisted tomography of intracranial CSF circulation using a water-soluble contrast medium.

Authors:  T Greitz; T Hindmarsh
Journal:  Acta Radiol Diagn (Stockh)       Date:  1974-09

3.  A cisternographic classification of hydrocephalus.

Authors:  A E James; P F New; E R Heinz; F J Hodges; F H DeLand
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1972-05

4.  Computerized transverse axial scanning (tomography). 2. Clinical application.

Authors:  J Ambrose
Journal:  Br J Radiol       Date:  1973-12       Impact factor: 3.039

5.  Prognostic criteria for cerebrospinal fluid shunting from isotope cisternography in communicating hydrocephalus.

Authors:  D C McCullough; J C Harbert; G Di Chiro; A K Ommaya
Journal:  Neurology       Date:  1970-06       Impact factor: 9.910

6.  Computer cisternography in the diagnosis of communicating hydrocephalus.

Authors:  T Hindmarsh; T Greitz
Journal:  Acta Radiol Suppl       Date:  1975

7.  Cerebrospinal fluid imaging using serial metrizamide CT cisternography.

Authors:  B P Drayer; A E Rosenbaum; H B Higman
Journal:  Neuroradiology       Date:  1977-03-28       Impact factor: 2.804

  7 in total
  2 in total

1.  Experiences with intrathecally enhanced computed tomography.

Authors:  B Hammer
Journal:  Neuroradiology       Date:  1980       Impact factor: 2.804

2.  Normal pressure hydrocephalus: correlation between CT and measurements of cerebrospinal fluid dynamics.

Authors:  M Kosteljanetz; H M Ingstrup
Journal:  Acta Neurochir (Wien)       Date:  1985       Impact factor: 2.216

  2 in total