Literature DB >> 7397390

Automated ektacytometry: a new method of measuring red cell deformability and red cell indices.

M Bessis, N Mohandas, C Feo.   

Abstract

The automated ektacytometer enables rapid measurement of red cell deformability by using small aliquots of blood (25 microliter). By subjecting red cells to varying shear stress in suspending media of different osmolalities, one can identify separate contributions of membrane viscoelastic properties, internal viscosity, and surface area-to-volume ratio to overall cellular deformability. The influence of drugs on red cell deformability can also be investigated. Analysis of the diffraction pattern of red cells that are aligned in the ektacytometer at minimal shear stress enables improved measurement of red cell diameter. Modern computerized image analysis can further improve the reliability of this measurement. Volume measurement of red cells of unusual shape is possible. since, under certain conditions, they transform into uniform ellipsoids in the ektacytometer. Aided again by improved image analysis, simple accurate computation of red cell volume becomes possible Ektacytometric measurement may provide a sensitive assessment of the overall functional integrity of living red cells or subpopulations of red cells. As such, these measurements are of research interest and may have major clinical utility.

Mesh:

Year:  1980        PMID: 7397390

Source DB:  PubMed          Journal:  Blood Cells        ISSN: 0340-4684


  24 in total

1.  Shear-induced alignment of self-associated hemoglobin in human erythrocytes: small angle neutron scattering studies.

Authors:  C J Garvey; R B Knott; E Drabarek; P W Kuchel
Journal:  Eur Biophys J       Date:  2004-05-06       Impact factor: 1.733

Review 2.  The clinical importance of erythrocyte deformability, a hemorrheological parameter.

Authors:  F C Mokken; M Kedaria; C P Henny; M R Hardeman; A W Gelb
Journal:  Ann Hematol       Date:  1992-03       Impact factor: 3.673

3.  The ring-infected erythrocyte surface antigen (RESA) of Plasmodium falciparum stabilizes spectrin tetramers and suppresses further invasion.

Authors:  Xinhong Pei; Xinhua Guo; Ross Coppel; Souvik Bhattacharjee; Kasturi Haldar; Walter Gratzer; Narla Mohandas; Xiuli An
Journal:  Blood       Date:  2007-04-27       Impact factor: 22.113

Review 4.  Biomechanical properties of red blood cells in health and disease towards microfluidics.

Authors:  Giovanna Tomaiuolo
Journal:  Biomicrofluidics       Date:  2014-09-17       Impact factor: 2.800

5.  The mechanical properties of stored red blood cells measured by a convenient microfluidic approach combining with mathematic model.

Authors:  Ying Wang; Guoxing You; Peipei Chen; Jianjun Li; Gan Chen; Bo Wang; Penglong Li; Dong Han; Hong Zhou; Lian Zhao
Journal:  Biomicrofluidics       Date:  2016-03-11       Impact factor: 2.800

6.  Red cell membrane disorders: structure meets function.

Authors:  Mary Risinger; Theodosia A Kalfa
Journal:  Blood       Date:  2020-09-10       Impact factor: 22.113

7.  Towards microfluidic-based depletion of stiff and fragile human red cells that accumulate during blood storage.

Authors:  Sha Huang; Han Wei Hou; Tamir Kanias; Jonas Tadeu Sertorio; Huichao Chen; Derek Sinchar; Mark T Gladwin; Jongyoon Han
Journal:  Lab Chip       Date:  2015-01-21       Impact factor: 6.799

8.  Measuring Deformability and Red Cell Heterogeneity in Blood by Ektacytometry.

Authors:  Nermi L Parrow; Pierre-Christian Violet; Hongbin Tu; James Nichols; Corinne A Pittman; Courtney Fitzhugh; Robert E Fleming; Narla Mohandas; John F Tisdale; Mark Levine
Journal:  J Vis Exp       Date:  2018-01-12       Impact factor: 1.355

9.  Dynamic deformability of Plasmodium falciparum-infected erythrocytes exposed to artesunate in vitro.

Authors:  Sha Huang; Andreas Undisz; Monica Diez-Silva; Hansen Bow; Ming Dao; Jongyoon Han
Journal:  Integr Biol (Camb)       Date:  2013-02       Impact factor: 2.192

10.  Measuring cell mechanics by optical alignment compression cytometry.

Authors:  Kevin B Roth; Charles D Eggleton; Keith B Neeves; David W M Marr
Journal:  Lab Chip       Date:  2013-04-21       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.