Literature DB >> 7391346

Displacement of catheters inserted through internal jugular veins with neck flexion and extension. A preliminary study.

I Curelaru, L E Linder, B Gustavsson.   

Abstract

Displacement of central venous catheters inserted through internal jugular veins in adult man was estimated on chest x-rays in six patients and measured in six corpses. The downward displacement of the catheter tips with maximum neck flexion varied between 1.0 and 2.0 cm in patients, and between 1.0 and 2.5 cm in corpses. The upward displacement with maximum neck extension varied between 0.5 to 1.0 cm in patients and 0.5 to 1.5 cm in corpses. The total displacement varied between 1.5 to 3.0 cm in patients, and 1.5 to 4.0 cm in corpses. The geater displacement in corpses might be explained by detachment of sternocleidomastoid muscles, and by resection of the sternum and anterior ribs, performed for access to the heart and superior vena cava. There was no apparent correlation between the side and site of the vein puncture, body length, sternocleidomastoid length, distances from the punction sites to suprasternal notch, and values of the displacements of the catheter tips in any group. To avoid rhythm disturbances and perforation of the heart (possible complications of the catheter displacement), the necessity of locating central venous catheter tips 3.0 to 4.0 cm above the superior vena cava-right atrial junction, and firm fixation of the catheter is stressed.

Entities:  

Mesh:

Year:  1980        PMID: 7391346     DOI: 10.1007/bf01757300

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  21 in total

1.  Alteration of endotracheal tube position. Flexion and extension of the neck.

Authors:  P A Conrardy; L R Goodman; F Lainge; M M Singer
Journal:  Crit Care Med       Date:  1976 Jan-Feb       Impact factor: 7.598

2.  Contrast-medium tamponade following insertion of a central venous catheter.

Authors:  S Ross
Journal:  Anesthesiology       Date:  1974-11       Impact factor: 7.892

3.  Optimal placement of cardiac catheter tip in ventriculoatriostomy. Technical note.

Authors:  K Sakata; S Ueda; Y Kashiki; T Taketomo
Journal:  J Neurosurg       Date:  1969-05       Impact factor: 5.115

4.  Perforation of the right ventricle by electrode catheters: a review and report of nine cases.

Authors:  J A Meyer; K Millar
Journal:  Ann Surg       Date:  1968-12       Impact factor: 12.969

5.  Displacement of right atrial and endotracheal catheters with neck flexion.

Authors:  A L Lingenfelter; R A Guskiewicz; E S Munson
Journal:  Anesth Analg       Date:  1978 May-Jun       Impact factor: 5.108

6.  Morbid and mortal complications associated with prolonged central venous cannulation. Awareness, recognition, and prevention.

Authors:  J H Henzel; M S DeWeese
Journal:  Am J Surg       Date:  1971-05       Impact factor: 2.565

7.  A new approach to percutaneous catheterization of the internal jugular vein.

Authors:  T L Rao; A Y Wong; M R Salem
Journal:  Anesthesiology       Date:  1977-05       Impact factor: 7.892

8.  Appraisal of the dislocation of central venous catheter tips using subclavian and arm veins.

Authors:  B van Dijk; P M Bakker
Journal:  Anaesthesist       Date:  1977-03       Impact factor: 1.041

9.  The anatomy of infraclavicular subclavian vein catheterization and its complications.

Authors:  D A Moosman
Journal:  Surg Gynecol Obstet       Date:  1973-01

10.  [Special technique for the catheterization of "central" veins (Seldinger's or indirect technique) (author's transl)].

Authors:  R Nessler
Journal:  Prakt Anaesth       Date:  1978-04
View more
  3 in total

1.  Delayed recognition of vascular complications caused by central venous catheters.

Authors:  C B Kapadia; S O Heard; N S Yeston
Journal:  J Clin Monit       Date:  1988-10

2.  Current problems in central venous catheter systems.

Authors:  J L Peters
Journal:  Intensive Care Med       Date:  1982       Impact factor: 17.440

3.  Intratumoral migration of central venous catheter in a patient with malignant bronchial carcinoid.

Authors:  Ranvinder Kaur; Tanvir Samra; Lalita Chaudhary; Aruna Jain
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Jul-Sep
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.