R M Smith, D Doran, M Mazur, B Bush.
Abstract
Zinc protoporphyrin and protoporphyrin free acid in blood were determined by high-performance liquid chromatography on a C18 column. Results for 63 human blood samples obtained through a lead poisoning detection program compared favorably with the widely-used ethyl acetate--acetic acid extraction determination. Blood from 16 rats which had been maintained on water heavily spiked with chloroform or bromodichloromethane and blood from a lead-poisoned cow were examined by this procedure.Entities:
Mesh:
Substances:
Year: 1980 PMID: 7391148 DOI: 10.1016/s0378-4347(00)81134-2
Source DB: PubMed Journal: J Chromatogr