Literature DB >> 738290

Dead-time correction in dynamic radionuclide studies by computer.

V Ullmann, V Husák, L Dubroka.   

Abstract

Several methods for the measurement of dead time and for evaluation of the dependencies required to correct dynamic studies for dead-time losses are described. Two program variants were written to produce time-activity curves in the selected areas of interest of the dynamic studies with computer's correction of dead-time losses; these variants are part of the system of programs for complex processing of scintigraphic studies set up for a Clincom instrument. The first variant performs correction on the basis of the registered count rate in the whole image, while the second variant makes us of the additional reference source positioned on the periphery of the camera visual field.

Mesh:

Year:  1978        PMID: 738290     DOI: 10.1007/bf00256644

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  9 in total

1.  Camera deadtime: rate-limiting factor in quantitative dynamic studies.

Authors:  M Ben-Porath
Journal:  Int J Nucl Med Biol       Date:  1975-07

2.  Deadtime correcton in high count rate quantitative dynamic studies with computer-assisted Anger-cameras.

Authors:  A Rossi; E Bevilacqua; G Guidarelli; C Danielli; R Zuin
Journal:  Ric Clin Lab       Date:  1976 Apr-Jun

3.  Deadtime characteristics of Anger cameras.

Authors:  J A Sorenson
Journal:  J Nucl Med       Date:  1975-04       Impact factor: 10.057

4.  Methods of correcting Anger camera deadtime losses.

Authors:  J A Sorenson
Journal:  J Nucl Med       Date:  1976-02       Impact factor: 10.057

5.  [The lag of a scintillation camera (Rho-Gamma III HP)].

Authors:  P Woller; V Hu sak; V Ullmann
Journal:  Radiobiol Radiother (Berl)       Date:  1976

6.  New calculating and control system for the Clincom apparatus.

Authors:  V Ullmann
Journal:  Nuklearmedizin       Date:  1977-08       Impact factor: 1.379

7.  The influence of true counting rate and the photopeak fraction of detected events on Anger camera deadtime.

Authors:  J E Arnold; A S Johnston; S M Pinsky
Journal:  J Nucl Med       Date:  1974-06       Impact factor: 10.057

8.  Methods for calculating the deadtime of Anger camera systems.

Authors:  R Adams; D Zimmerman
Journal:  J Nucl Med       Date:  1973-07       Impact factor: 10.057

9.  A correction method for high-count-rate quantitative radionuclide angiography.

Authors:  G S Freedman; T Kinsella; A Dwyer
Journal:  Radiology       Date:  1972-09       Impact factor: 11.105

  9 in total
  1 in total

1.  Dynamic scintigraphy with high temporal resolution. Phase dynamic studies of rapid periodical processes.

Authors:  V Ullmann; L Dubroka; O Kuchar; J Kuba
Journal:  Eur J Nucl Med       Date:  1980
  1 in total