Literature DB >> 7377779

Microbial prevalence in domestic humidifiers.

H A Burge, W R Solomon, J R Boise.   

Abstract

The prevalence of viable thermophilic bacteria and actinomycetes and mesophilic fungi was examined in 145 samples from 110 domestic humidifiers. A total of 72 and 43% of furnace and console humidifier samples, respectively, contained viable thermophilic bacteria, whereas 60 and 72% of these samples produced mesophilic fungal growth. Thermophilic actinomycetes were recovered from seven humidifier samples. Efforts to detect thermophilic actinomycete antigens in 15 humidifier fluid samples were not successful. Antifoulants added to humidifier fluid reservoirs had no apparent effect on microbial frequency. Airborne microbial recoveries did not reflect patterns of humidifier contamination with respect to either kinds or numbers of microorganisms in 20 homes in which volumetric air samples were obtained during humidifier operation.

Entities:  

Mesh:

Year:  1980        PMID: 7377779      PMCID: PMC291430          DOI: 10.1128/aem.39.4.840-844.1980

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  15 in total

1.  Assessing fungus prevalence in domestic interiors.

Authors:  W R Solomon
Journal:  J Allergy Clin Immunol       Date:  1975-09       Impact factor: 10.793

2.  Fungus aerosols arising from cold-mist vaporizers.

Authors:  W R Solomon
Journal:  J Allergy Clin Immunol       Date:  1974-10       Impact factor: 10.793

3.  Pseudomonas in ventilators.

Authors:  R Y Cartwright; P R Hargrave
Journal:  Lancet       Date:  1970-01-03       Impact factor: 79.321

4.  Bacterial emission from both vapor and aerosol humidifiers.

Authors:  H D Covelli; J Kleeman; J E Martin; W L Landau; R L Hughes
Journal:  Am Rev Respir Dis       Date:  1973-09

5.  Studies of a new humidifying device as a potential source of bacterial aerosols.

Authors:  T Schulze; E B Edmondson; A K Pierce; J P Sanford
Journal:  Am Rev Respir Dis       Date:  1967-09

6.  A simplified application of the Andersen sampler to the study of airborne fungus particles.

Authors:  W R Solomon
Journal:  J Allergy       Date:  1970-01

7.  Epidemiologic studies relating thermophilic fungi and hypersensitivity lung syndromes.

Authors:  E F Banaszak; J Barboriak; J Fink; G Scanlon; D P Schlueter; A Sosman; W Thiede; G Unger
Journal:  Am Rev Respir Dis       Date:  1974-11

8.  Hypersensitivity pneumonitis due to contamination of home humidifier.

Authors:  D R Tourville; W I Weiss; P T Wertlake; G M Leudemann
Journal:  J Allergy Clin Immunol       Date:  1972-04       Impact factor: 10.793

9.  Interstitial pneumonitis due to hypersensitivity to an organism contaminating a heating system.

Authors:  J N Fink; E F Banaszak; W H Thiede; J J Barboriak
Journal:  Ann Intern Med       Date:  1971-01       Impact factor: 25.391

10.  Presence of thermophilic acintomycetes in residential heating systems.

Authors:  J N Fink; A J Resnick; J Salvaggio
Journal:  Appl Microbiol       Date:  1971-10
View more
  5 in total

1.  Examination of fungi in domestic interiors by using factor analysis: correlations and associations with home factors.

Authors:  H J Su; A Rotnitzky; H A Burge; J D Spengler
Journal:  Appl Environ Microbiol       Date:  1992-01       Impact factor: 4.792

2.  Source, significance, and control of indoor microbial aerosols: human health aspects.

Authors:  J C Spendlove; K F Fannin
Journal:  Public Health Rep       Date:  1983 May-Jun       Impact factor: 2.792

3.  Dustborne fungi in large office buildings.

Authors:  Hsing Jasmine Chao; Donald K Milton; Joel Schwartz; Harriet A Burge
Journal:  Mycopathologia       Date:  2002       Impact factor: 2.574

4.  Mycobacterium gordonae-induced humidifier lung.

Authors:  Harue Utsugi; Yutaka Usui; Fuyumi Nishihara; Minoru Kanazawa; Makoto Nagata
Journal:  BMC Pulm Med       Date:  2015-09-30       Impact factor: 3.317

5.  Indirect health effects of relative humidity in indoor environments.

Authors:  A V Arundel; E M Sterling; J H Biggin; T D Sterling
Journal:  Environ Health Perspect       Date:  1986-03       Impact factor: 9.031

  5 in total