Literature DB >> 7369841

Torque curves produced at the knee during isometric and isokinetic exercise.

G N Scudder.   

Abstract

Torque curves recorded during knee extension and flexion at various speeds of isokinetic effort and at selected positions of isometric effort were studied to determine the amount of torque generated at selected speeds of motion, the point in the arc of motion where maximal torque output occurred, the relationship between isometric and isokinetic torques, the relative value of knee flexion and extension torques at various speeds, and the constancy of results in isokinetic testing. The isokinetic torques produced were less than isometric values and decreased as the rate of motion increased. Production of peak torque output occurred later in the arc of motion as the speed of contraction increased in extension. No significant change in the relative ability of the flexors and extensors was seen as a rate of motion increased. Isokinetic test-retest differences were similar at the rates of motion tested.

Mesh:

Year:  1980        PMID: 7369841

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  6 in total

1.  Open-loop position control of the knee joint using electrical stimulation of the quadriceps and hamstrings.

Authors:  J M Hausdorff; W K Durfee
Journal:  Med Biol Eng Comput       Date:  1991-05       Impact factor: 2.602

Review 2.  Isokinetic dynamometry. Applications and limitations.

Authors:  V Baltzopoulos; D A Brodie
Journal:  Sports Med       Date:  1989-08       Impact factor: 11.136

3.  Effects of joint angle, electrodes and waveform on electrical stimulation of the quadriceps and hamstrings.

Authors:  D R McNeal; L L Baker
Journal:  Ann Biomed Eng       Date:  1988       Impact factor: 3.934

4.  Simulation-Based Design for Wearable Robotic Systems: An Optimization Framework for Enhancing a Standing Long Jump.

Authors:  Carmichael F Ong; Jennifer L Hicks; Scott L Delp
Journal:  IEEE Trans Biomed Eng       Date:  2015-07-30       Impact factor: 4.538

5.  Isokinetic evaluation of knee extensor/flexor muscle strength in patients with hypermobility syndrome.

Authors:  Nilay Sahin; Akin Baskent; Hatice Ugurlu; Ender Berker
Journal:  Rheumatol Int       Date:  2007-11-28       Impact factor: 2.631

6.  Prediction of peak torque and contraction work at different isokinetic angular velocities of plantarflexion.

Authors:  B Gerdle; A R Fugl-Meyer
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1986
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.