Literature DB >> 7369348

Contractile properties of transplanted extensor digitorum longus muscles of cats.

J A Faulkner, J H Niemeyer, L C Maxwell, T P White.   

Abstract

Following autologous transplantation of whole extensor digitorum longus (EDL) muscles of cats into the EDL site, we investigated the degree and time course of restoration of contractile properties of autografts toward control values. Isometric and isotonic contractile properties of 66 autografted EDL muscles were measured in situ from 40 to 440 days following transplantation. The control value for maximum tetanus tension (P0) was 27 N. The mean P0 for the autografts increased from 2% of control 40 days after transplantation to 26% 440 days after transplantation. When P0 was normalized per square centimeter of muscle fiber cross-sectional area, no significant difference was observed between the P0 of autografts (28 N/cm2) and controls. Compared to controls, autografts 40-179 days following transplantation had slower time to peak twitch tensions, half-relaxation times, and maximum velocities of shortening and smaller twitch-tetanus tension ratios. Between 180 and 440 days after transplantation, values for autografts approached control values. Autografts fatigued more than twice as rapidly as controls.

Entities:  

Mesh:

Year:  1980        PMID: 7369348     DOI: 10.1152/ajpcell.1980.238.3.C120

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  6 in total

Review 1.  The relationship of neck injury and post-traumatic headache.

Authors:  Russell C Packard
Journal:  Curr Pain Headache Rep       Date:  2002-08

2.  Levator force generation in normal subjects.

Authors:  B R Frueh; D C Musch
Journal:  Trans Am Ophthalmol Soc       Date:  1990

Review 3.  Moving and positioning the nucleus in skeletal muscle - one step at a time.

Authors:  Bruno Cadot; Vincent Gache; Edgar R Gomes
Journal:  Nucleus       Date:  2015       Impact factor: 4.197

Review 4.  The measurement of maximal (anaerobic) power output on a cycle ergometer: a critical review.

Authors:  Tarak Driss; Henry Vandewalle
Journal:  Biomed Res Int       Date:  2013-08-29       Impact factor: 3.411

5.  Factors causing difference in force output among motor units in the rat medial gastrocnemius muscle.

Authors:  K Kanda; K Hashizume
Journal:  J Physiol       Date:  1992-03       Impact factor: 5.182

Review 6.  Graves' eye disease: orbital compliance and other physical measurements.

Authors:  B R Frueh
Journal:  Trans Am Ophthalmol Soc       Date:  1984
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.